    Ideal Classic HE15 (with Boilermate OV Class A) finally packed up what to do...

    It was rust in the end that made them not fix it. They were quite fair and send another more senior guy to look at it who agreed, casing not safe. Just dumb that the first guy didn't tell me in the first place. Replaced with a baxi 415 for like £2k, working well so far!
  2. P

    Replaced heat only boiler now overheating

    Blocked condensate drain! Now fixed
  3. P

    Replaced heat only boiler now overheating

    It was the pipes. A long time later engineer came and swapped the pipes and then it worked just fine, for two days.... Yesterday I heard lots of bubbling gurgling kettling and it was instantly overheating. Now today it keeps restarting won't really fire properly, hear a bit of bubbles then it...
  4. P

    Replaced heat only boiler now overheating

    That was my first potential solution but temp knob has a sticker as I'm not supposed to mess with it yet! Swapping directions sounds slightly better :)
  5. P

    Replaced heat only boiler now overheating

    Good question, it's not commissioned, he left as my system takes many hours to fill. He tested it briefly when partially full and it was overheating we thought maybe it would stop when full. He was supposed to come back today to comission it but I checked if it was working once full yesterday...
  6. P

    Replaced heat only boiler now overheating

    Yes all correct John (except the old one is a classic HE), I'm not sure if the engineer didn't check if there was a crossover when he removed it, once it was off we agreed return left and flow right on old and new boiler but somehow it's ended up reversed. No bother he will come back and switch...
  7. P

    Replaced heat only boiler now overheating

    Now that I'm thinking about pretty sure the left side (return) was getting hotter than the flow side. Oh dear I really don't want to have to drain this down again...
  8. P

    Replaced heat only boiler now overheating

    I guess it's possible why are you guessing that? The gas engineer took the pipes from the previous boiler left return and right flow so unlikely to be wrong.
  9. P

    Replaced heat only boiler now overheating

    I had an ideal classic he 15 heat only boiler running a boilermate ov class a thermal store. The thermal store has a grundfos 15/60 pump on the boiler return. Replaced with a baxi 415 (because no overrun and no live required which simplifies things). Thermal store refilled all things working...
  10. P

    Draining boilermate ov class a

    Interestingly I have a connection with a relief valve between boiler flow and central heating return but I'm guessing this is just a precaution and shouldn't impact draining and filling?
  11. P

    Draining boilermate ov class a

    About to have my broken boiler replaced this weekend and trying to figure out how to drain the old one properly with this system to be ready for the engineer. It's an open vented thermal store. As far as I understand this boilermate has a cylinder and 3 independent loops (boiler, central...
  12. P

    Ideal Classic HE15 (with Boilermate OV Class A) finally packed up what to do...

    Shambles, they told me they had the old fan and PCB parts in stock, engineer came over said yeah PCB and fan shot but I don't have any on me, I'll write a report don't know what will happen. Then I get a voice mail saying boiler deemed beyond repair so now they want to keep £99 for the callout...
  13. P

    Ideal Classic HE15 (with Boilermate OV Class A) finally packed up what to do...

    Ok they told me over the phone PCB and fan are in their old stock and they don't have a problem with the boilermate (of course they won't repair it or anything) so all sounds good, booking in ASAP, will let you know how it goes :) thanks for the suggestions to get it repaired.
  14. P

    Ideal Classic HE15 (with Boilermate OV Class A) finally packed up what to do...

    Yes they figured out age from serial, they're slightly worried about getting parts (I see plenty online) but otherwise happy to come.
  15. P

    Ideal Classic HE15 (with Boilermate OV Class A) finally packed up what to do...

    Ideal are happy to come out for £359 (£99 if they can't fix) but won't touch the boilermate tank. Does this sound sensible?