Recent content by pops547

  1. P

    replacing bakelite fuses with mcb's

    Thanks guys the unit has 4 fuses in and the guy that had the house before me put an extra unit in for a shower that's been removed but the wiring's still there so I think its time for a new unit cheers once again
  2. P

    replacing bakelite fuses with mcb's

    I've got the old bakelite wire fuses and I want to put mcb's in, the old one's are 2 pin and the new are 4 how do you get round this or do I need to get someone in to change the consumer unit
  3. P

    new hot water cylinder

    cheers for that guys I'll see which is easiest 2/3rds from the top or 1/3rd from the bottom !! Dave
  4. P

    new hot water cylinder

    I need to fit a new hot water cylinder where do you fit the tank stat on the new foam covered cylinders cheers
  5. P

    central heating

    Cheers for that looks like it may be time to modify things possibly explain why the gas bill is so high Dave
  6. P

    central heating

    I've had a look all round and can only find 1 2 port valve on the tank itself unless they are under the floorboards but I can't see any cables going that way
  7. P

    central heating

    Cheers Guys thanks for that I'll give it a try one other thing I've noticed reading other topics on the forum they seem to say there should be 2 zone valves, 1 operated by a room stat and 1 operated by the tank stat I only have the 1 operated by the tank stat is that correct?
  8. P

    central heating

    the boiler is a Gloworm Space Saver II and on the cylinder is an ACL Lifestyle 2 port motorised valve apart from that just the normal tank stat, pump and radiators ect. when you move the switch on the valve manually it brings the pump on and when the programmer brings the water on the pump comes...
  9. P

    central heating

    Hi when I have the central heating off on the programmer and leave the water on, the water comes on but the radiators still get hot any idea's would be helpfull cheers
  10. P

    shower booster pump

    I'm putting a booster pump in but the current tank is not big enough to supply both shower and bath/basin and no room where it is to put bigger one in. Can I supply the hot water direct from the cylinder via a york flange and put a separate tank just to supply the pump with cold water or do both...
  11. P

    glass fibre roofing

    I'm looking to put a glass fibre roof on my dormer and wondered who are the best people to get the stuff from also the boards need replacing 18mm are a bit heavy to get to up to where it is, is there any reason why I can't put 11mm boards and then 9mm boards on top
  12. P

    cw tanks

    Hi I'm fitting a shower cabin that has body jets shower head ect and a booster pump (2 bar) it recomends a 50 gall tank min but mine is only a 35 gall approx. I cant get a bigger tank in can I put a second tank in the loft the other side of the wall say 25 gall and connect it to the first one...
  13. P

    surrey flange

    cheers for that guys I hadn't heard of a york flange I'll get one and get it sorted
  14. P

    surrey flange

    Yeah I realise that but my tank has the male 1" thread on the tank so the surrey flange wont fit thats the problem I've got
  15. P

    surrey flange

    Hi I want to fit a surrey flange to the cylinder to connect to a shower pump but the fitting on the top of my tank is a male fitting looks about 1" BSP. I've checked to see if it is an adaptor but it appears to be part of the tank. there is a female fitting to a 22mm pipe coming off there going...
Back