Recent content by ryetee

  1. R

    Bath thingy

    I want to replace the bath thingy. Not sure what it's official name is but I'm talking about the chrome strainer where the plug itself sits. Mine has a screw in the middle. It's it just a case of unscrewing that and replacing with a suitable sized new one. Or will the unscrewing cause the bit...
  2. R

    Hotpoint BF1620 wont work

    actually I'm not going to presume she's done everything right !! knowing I'll not get a straight answer is there anything that will stop it working like 1. not selecting any cycle 2. not putting any detergent and leaving detergent door open 3. no salt in machine 4. anything else
  3. R

    Hotpoint BF1620 wont work

    MY daughter is having problems with her dishwasher. There is a switch in the door which she switches to on (a light then comes on) but when she closes the door nothing happens, I presume she's done everything else right. Btw - will these dishwashers work if there is no salt in them?
  4. R

    Hotpoint BF1620 wont work

    Managed to post this twice and can't delete so please ignore this one! MY daughter is having problems with her dishwasher. There is a switch in the door which she switches to on (a light then comes on) but when she closes the door nothing happens, I presume she's done everything else right...
  5. R

    Light in walk in cupboard

    Apparently I had connected everything right. Electrician came in and couldn't find a problem until he went into the socket and found that the supply lead to my FCU was brittle and broke off when he was checking things out. HE sorted that all out reconnected everyhting in the way I had done and...
  6. R

    Light in walk in cupboard

    John - as per later posts I'm getting an electrician in but do you know what the problem is?
  7. R

    Light in walk in cupboard

    I'd actually redone that after I had taken the photo. It probably wasn't under the screw but it was a lot further in. There's an earth from supply going to FCU. No earth from load. There's an earth connecter on the FCU where the earth from the supply went. There is also an earth on the...
  8. R

    Light in walk in cupboard

    Don't know off hand but looked a 'standard' size. Couple of inches or so from memory. Why do you ask?
  9. R

    Light in walk in cupboard

    Right latest saga - after taking the light switch off to photograph for one of the posts I put it back. Followed the instructions and same wires went in same holes. Still the same effect red lamp comes on when no bulb in but light and bulb don't work when there is one in. The wall socket...
  10. R

    Light in walk in cupboard

    The supply has an earth. There are only 2 cables going to the lamp.
  11. R

    Light in walk in cupboard

    i've tried the neutral (from the supply - none on the load) into the connector on the light itself and also the housing too.
  12. R

    Light in walk in cupboard

    OK I'm stuck here's the photo top left says load/l1 on right is eart middle left says supply/l bottom left says load/n1 bottom right says supply/n (supply is written vertically) and from another view
  13. R

    Light in walk in cupboard

    OK Will do, but I took the supply (from the socket) and put the red supply in the hole that says supply L the black in supply N and then red Load into Load L and black load into LOad N. Am I getting my supply and load mixed up? Having googled it I don't think I am. Not in a position to...
  14. R

    Light in walk in cupboard

    double checked the instruction - all are in right hole and gripped - I tried pulling them out by hand
  15. R

    Light in walk in cupboard

    //www.diynot.com/network/ryetee/albums/22416 Hope this explains what i've done. had to do this in a hurry so will explain further when i get a mo
Back
Top