Recent content by shugrover

  1. S

    Fireplace Backboard

    Hi, did you ever find any suitable adhesive? I have a similar problem, and I am after high temp tiles too.
  2. S

    Fireplace Cement

    Hi, I have an open fireplace, I have re-rendered the rear of the fireplace, the grate I have has a large metal back to help deflect the heat, but my problem is the cement has now cracked again. How do I stop this happening? Is there any high temp ceramic tiles that I can tile the rear and sides...
  3. S

    Linea 24 Where do I buy pressure release valve?

    Thanks for that, thats the one!!
  4. S

    Linea 24 Where do I buy pressure release valve?

    Thanks, have done quick check, they don't list the release valve?
  5. S

    Linea 24 Where do I buy pressure release valve?

    Hi, after replacing the Plate heat exchanger I also now need to replace the pressure release valve, as it is seeping out the pipe to outside, I have had it apart, cleaned it up, but rusty marks on rubber not dealing properly, also I cleaned the brass seat for it too so that is now perfect, but...
  6. S

    Linea 24 How do I reduce flow rate.

    Which bit is the flowmeter?
  7. S

    Linea 24 How do I reduce flow rate.

    Yeah, thanks, just thought there would be something simple to adjust.
  8. S

    Linea 24 How do I reduce flow rate.

    Old one had corroded so much was blocking flow, and leaking through, new one flows so much water it doesn't get hot enough. Just going to reduce taps as its easier. :D
  9. S

    Linea 24 How do I reduce flow rate.

    Yeah understand what you are saying, but I did not explain properly, the tap is normally at 12, when you turn it to the 9 position, it shuts off water to everything, when you turn it to the 6 position its then open to pressurize the system, as it starts to open at 7. My line of thought was...
  10. S

    Linea 24 How do I reduce flow rate.

    So, this boiler does not have any flow rate adjustment built into it then? I cannot see anything to adjust anywhere. I guess I can just turn the filling valve off slightly to reduce flow? If you have the hot tap running when you want to re pressurize the system, it turns off the water going into...
  11. S

    Linea 24 How do I reduce flow rate.

    Cheers Dave for that suggestion, I can do that, but kids and ex wives have problems remembering! :roll: This human thingy, er, the only thing in bottom right corner is the valve for the filling loop, the pipe from the heat exchanger drops straight out the bottom of boiler to the hot taps.
  12. S

    Linea 24 How do I reduce flow rate.

    Thanks, cannot see anything that can be adjusted, will go and have another look, looks like the pipe comes straight from the plate heat exchanger, probably wrong, but will go and check again.
  13. S

    Linea 24 How do I reduce flow rate.

    Hi all, have just fitted a new plate heat exchanger to the boiler, cleaned out the pressure release valve as that was leaking too, now boiler works fine without loosing pressure or tripping the overheat, but hot water too the taps it way to fast so its running at 40 as shown on front of boiler...
  14. S

    Vokera Linea 24 No Display/almost dead

    Cheers, so the secondary heat exchanger is possibly leaking too? It has sort of rusty metal flakes that come out when I tap it on the ground then flush it through. ANyone have a pdf install manual for this? I cannot find any links to download one from Vokera's website.
  15. S

    Vokera Linea 24 No Display/almost dead

    Thanks, its definatley water, and lots of it if I hold the valve open, the one on top of pressure vessel.
Back
Top