Recent content by sideshowbob

  1. S

    Peugot Extpert flat bettery

    thanks Stivino
  2. S

    Peugot Extpert flat bettery

    Hi, The battery on my expert van keeps going flat, first of all over the weekend when i doint use it and now over night. It looks quite new and the MOT guy did a resistasnce check on it and said it came out ok. As a workround i though that if i disconect the live when i'm not using it...
  3. S

    Minor works certificate "opertation of equipment"

    sorry, i've not managed to get a pic up but its the Ethos 7901 domestic minor works certificate (bought from CEF) and in the "Part 3 Essential Tests" it lists... Earth Continuity Polarity Insulation resistance Earth fault loop impedance RCD rated residential current Operation of...
  4. S

    Minor works certificate "opertation of equipment"

    oh, thats great thanks, obviously i didn't actually want to know what it is for just so long as i know its not fpr that, really helpful cheers!
  5. S

    main and supplementary bonding

    i believe you just have to have a regonized qualification
  6. S

    main and supplementary bonding

    hmmm, so helpful, thanks, also, you dont have to be in a scheme to fill out a form you just have to be a competent person
  7. S

    main and supplementary bonding

    Hi Does anyone know the best way to fill out a minor works certificate for an upgrade of the main and supplementary bonding most of the questions refer to the specific circuit and as the work doesn't relate to any circuit in particular do the just get filled in as N/a Thanks
  8. S

    Minor works certificate "opertation of equipment"

    Hi On my Ethos 7901 domestic minor works certificate below the box for the RCD rating is a box marked "opertation of equipment" Is this form the RCD trip time? Thanks
  9. S

    Insulation resistance - low reading

    thanks for the replys, what i'm trying to figure out though is the possible/probable cause ie nail through cable, damp, ghosts Cheers
  10. S

    Changing one switch to double for extractor fan.

    You could use a 3 pole fan isolator switch, the fan would still come on with the light but could be switched off aswell. Could not be switched on on itsown though would have to be aditional switch though
  11. S

    Insulation resistance - low reading

    Its a mixture of fairly old instalation, probably 15 - 20 year, and new modifications some of which are in newish plaster
  12. S

    Insulation resistance - low reading

    Hi, I've tested all the circuits seperately and all reading have come back fine (>500 MOhms) except the test between Neutral and Earth of one of the lighting circuits which is 9 MOhms. Does anyone know why this might be Thanks
  13. S

    floorboards - secret nailing?

    Thanks chaps Easy when you know how eh!
  14. S

    floorboards - secret nailing?

    Hi How can i fix t and g floorboards so the nails dont show? tHANKS
  15. S

    Painting new plaster

    you could paint first with a mist coat to reduce the absorbancy of the new plaster. mist coat - 1 part pva, 1 part emulsion, 4 parts water. careful if you are rollering though as it sprays everywhere.
Back