Removing the text also doesn't remove the arming option via the keypad, when I select part arm I see evening arm and two blank (no text) arming options, part arm 2 and part arm 3.
Maybe there is not a way to remove part arm 2 and 3, all part arms show by default...
Hey sparkymarka I've removed the text under Part Arm Text, however that's hasn't removed the 2 options, just removed the text. See attached picture. I can still press on the middle and right boxes to arm the system.
I want to see only one option - evening arm
Hey all, some help please. Should be a quick one I hope.
I have the texecom premier panel. Currently when I go into my app or panel to set part arm I get 3 options
Evening
Bedroom 1
Bedroom 2
I actually only want to see the evening option in both the app and the panel. So only display 1 part...
Hey all
I replaced the pcb on my vaillant ecotec boiler, it's working fine.
However the wall thermostat is not working with the new pcb unit. So when I turn the thermostat down it doesn't turn the boiler off.
See photos. Any help with how to get this working?
I have MCB in the supply end, a 32Amp
The cave CU is British General which has an RCD 40A 30mA, MCB 32A and MCB 6A
So can use one of these for the armoured cable from supply
how much smaller?
Yes you might be right, it does seem there are different options, and a pro can look at the whole set up in details and advise I guess
Thanks ericmark. So my man cave will be similar, eventually will look at have a fridge freezer in there and maybe a hob oven etc.
There is a 10mm wire for the oven which I will put on a separate MCB.
So I think I'm going with connecting the armoured cable in the man cave to a 32A MCB, which...
A lot of advise there guys... Understanding parts of it, but not all !!
The building is an outbuilding, a man cave, so will have av equipment (TV etc) . And thinking of putting a kitchen in there later to host parties. For phase 1 I just wanted to get power to it and second fix the sockets and...
Oops sorry I meant MCB.
Understood re grey and black, this is how I found it, but can switch them.
Cable run is about 30 meters. I'll look at the earthing of the SWA.
Right understood, so what would you recommend?
Thanks for the replies all. The garage feed is earthed using the grey cable see picture 4 attached.
Using the correct terminology now - the garage is fed from a 32A MCD, so I could just put the same on the garage consumer, 32A MCD? I already have the consumer unit there so just to make it...