Recent content by Squiral1

  1. S

    Vaillant ecoTEC plus 637 Unvented System - Boiler Pressure

    Attached is the photo of tune vessel label, what should the pressure be and how to put pressure back in?
  2. S

    Vaillant ecoTEC plus 637 Unvented System - Boiler Pressure

    The pressure drops after a few days, could be longer, but depends on usage. Just having the hot water on can cause the pressure to drop after a week or so. Could the expansion vessel be faulty?
  3. S

    Vaillant ecoTEC plus 637 Unvented System - Boiler Pressure

    Hey I was hoping someone could help re boiler pressure with my Vaillant ecoTech plus 637. The pressure keeps dropping down to 0.4 bar, I top it up a little to get it back above 1 bar, than when I turn on the hot water, rads and underfloor heating, the pressure increases to above 3 bar. See...
  4. S

    Texecom premier all part arm options showing in app

    Okay thanks for testing. Removing the text also doesn't remove the arming option via the keypad, when I select part arm I see evening arm and two blank (no text) arming options, part arm 2 and part arm 3. Maybe there is not a way to remove part arm 2 and 3, all part arms show by default...
  5. S

    Texecom premier all part arm options showing in app

    Hey sparkymarka I've removed the text under Part Arm Text, however that's hasn't removed the 2 options, just removed the text. See attached picture. I can still press on the middle and right boxes to arm the system. I want to see only one option - evening arm
  6. S

    Texecom premier all part arm options showing in app

    How do I remove the names on the panel? I set all zones in bedroom 1 and bedroom 2 as off, but that hasn't removed the options
  7. S

    Texecom premier all part arm options showing in app

    Hey all, some help please. Should be a quick one I hope. I have the texecom premier panel. Currently when I go into my app or panel to set part arm I get 3 options Evening Bedroom 1 Bedroom 2 I actually only want to see the evening option in both the app and the panel. So only display 1 part...
  8. S

    Vaillant ecotec PCB replacement setting up thermostat

    Hey CountryFan removing the white 24v RT worked. Now the boiler is turning on and off via the thermostat. Thanks for your help
  9. S

    Vaillant ecotec PCB replacement setting up thermostat

    Okay let me try that. Thanks for your help CountryFan
  10. S

    Vaillant ecotec PCB replacement setting up thermostat

    Hey thanks for the reply. Which 24v link needs to be removed? The replacement was just reconnected like for like.
  11. S

    Vaillant ecotec PCB replacement setting up thermostat

    Hey all I replaced the pcb on my vaillant ecotec boiler, it's working fine. However the wall thermostat is not working with the new pcb unit. So when I turn the thermostat down it doesn't turn the boiler off. See photos. Any help with how to get this working?
  12. S

    Which RCD for Garage Consumer Unit, mains coming from house

    I'll look at various options and decide which is best to go down. I could fuse switch it, that is an option. The cave CU is there if needed.
  13. S

    Which RCD for Garage Consumer Unit, mains coming from house

    I have MCB in the supply end, a 32Amp The cave CU is British General which has an RCD 40A 30mA, MCB 32A and MCB 6A So can use one of these for the armoured cable from supply
  14. S

    Which RCD for Garage Consumer Unit, mains coming from house

    how much smaller? Yes you might be right, it does seem there are different options, and a pro can look at the whole set up in details and advise I guess
  15. S

    Which RCD for Garage Consumer Unit, mains coming from house

    Thanks ericmark. So my man cave will be similar, eventually will look at have a fridge freezer in there and maybe a hob oven etc. There is a 10mm wire for the oven which I will put on a separate MCB. So I think I'm going with connecting the armoured cable in the man cave to a 32A MCB, which...