Had a look at the ‘bisonframes’ website, their genesis flush sash
look quite good, very similar to the Decueninck windows with
Graf welded or mechanical joints,
not sure if pricing is similar.
Do not mind no arch top, still look good square, seen a few Residence9 bad reviews online though, jamming up & coming apart, not sure how true that is & I understand their Ali not upvc.
Not seen in a showroom , but
Deceuninck look good with 1930’s
style handles & stays too. I like the idea of...
Hi any window specialist.
I’m having a 2 floor extension on a 1930’s house with original
wooden casements fitted. I’m looking for a wood effect satin finish flush fit white casement, but not sure which company to use? I have seen sash windows on Kings House, a new development on Brighton...
My Potterton Lynx 2 demand & ignition lights are not coming on & boiler not firing up on either DHW or CH, although when CH is switched on pump is spinning & a relay on the PCB is clicking on but no lights or ignition or fire up.
No obvious loose wires & I wiggled PCB wired connections & tapped...
Yes, 2 clicks 1 when blown into and another when pressure released. pressure switch terminals as follows...
4 terminals in a row left to right. Using the continuity buzzer on my multi meter.....
1 and 3 terminals buzz when there is no pressure, showing a circuit.
2 and 3, 2 and 4, and 3 and...
Many thanks for replying to my post,
but why do you think its the pressure switch, I thought rising water levels pushes air up the tube activating the pressure switch, as there is no air entering my machine on rinse, the pressure switch can be discounted.
Yes I have swapped them all around, as no water is entering on the rinse cycle there will be no rising water to activate the pressure switch.
The flashing prewash light is a fault code signifying no water, but I know all valves are good & unblocked.
As stated earlier the machine works fine up...
Does not fill on the rinse just spins slowly, no water going in at that point at all, no holes in pre pipe, neither does it overfill,
works fine up to that point, the rinse valve is in working order.
My Hotpoint Aquarius washing machine WF250...
Prewash fine
Mainwash fine
drains good
All 3 solenoids tested, working fine & have water, no blockages in screens.
The prewash light flashes when a cycle gets to a rinse, no water at that point either?
Hotpoint online say this means no...
I have a plumbing question, any replies gratefully received.
I have a Ravenheat 820/20 T.
On the PCB is a single dial with an opening for a posidrive screwdriver, it turns both clockwise and anticlockwise. It has printed next to it ADJ. HEAT REG. RISC. What is this for?
Even though the...
Hi plumbernot,
If the boiler is over 10 years old the rubber seal in the PRV could be perished. Disconnect the boiler from the mains electricity FIRST and take the front cover off. Have a look where the overflow pipe reaches the boiler and you will see the valve. it should...