Recent content by stevethom2

  1. S

    Combi Boiler Room Thermostat Operates in Reverse

    Confirm faulty thermistat replaced and all in order. Thanks all for your help.
  2. S

    Combi Boiler Room Thermostat Operates in Reverse

    I've posted here imaged of: The inside of the room sensor showing the circuit diagram The internal connections to the programmer The wiring diagram for the programmer There is a link in the programmer diagram ( L to 1) that doesn't seem to have been done - could this be any cause?
  3. Untitled

    Untitled

  4. Untitled

    Untitled

  5. Untitled

    Untitled

  6. S

    Combi Boiler Room Thermostat Operates in Reverse

    Switching black from 3 to 4 has no effect.
  7. S

    Combi Boiler Room Thermostat Operates in Reverse

    Hi We recently moved into a property with a combi boiler system comprising a Camay 5 boiler, Drayton SM1 programmer and Danfoss RET230VF2 room thermostat. The system seems to work ok except that the room thermostat will only switch on when temperatures are increased at the dial (or...