  1. T

    Texecom 48 premiere Elite final installation

    Hi All, Wanted to find out if theres anyone available to finish of an installation (configuration) of the texecom elite alarm. Ive recently had a baby and haven't had a chance to finish off my brothers installation. Ive installed everything (door sensors, room sensors, GSM, Control Panel...
  2. T

    Texecom Elite Premier 48 - ComIP

    Excellent Secure I AM - Many thanks for that, it was the Elite 48 in the panel section that sorted the connectivity out. Manage to get online now. Thanks
  3. T

    Texecom Elite Premier 48 - ComIP

    Under Wintex new account panel details, I currently have the premier 48 v2.11 firmware. Im selecting Panel type Premier 48 and software version 2.x (ive tried 10.x as well) Serial number I cannot input anything and password is the default password for the panel. I will try what you have...
  4. T

    Texecom Elite Premier 48 - ComIP

    Thanks for the quick reply At the moment Im using 192.168.1.150 for the Panel and the router has an IP address of 192.168.1.1. I haven't set port forwarding on the router as of yet as its all internal configuration at the moment and in the past on another install I didnt set any port...
  5. T

    Texecom Elite Premier 48 - ComIP

    Hi All, Ive recently installed aTexecom Premier 48 unit with 8 PIR detectors, 3 Door impact sensors and one bell. The extra modules are ComIP and the GSM module. Ive configured the IP address via the keypad set the Subnet, Gateway and the default port of 10001. Ive tried everything to try...
  6. T

    New Texecom Alarm

    Excellent, thanks for the confirmation
  7. T

    New Texecom Alarm

    Hi All, I would like some advise for a new alarm that im intending on buying. I have listed the items below and wanted to find out if all is compatible with the elite 48 control panel and if 3 keypads can be installed. 1x Texecom Premier elite 48 3x Texecom Premier Elite Diamond Black...
  8. T

    Aico Smoke Alarms beeping

    Hi All Was I dreaming yesterdat that a responce was posted here. It suggested in contacting Aico, which I will do this morning to see if I can get the remote and CO2 swapped out after all the tests and money spent on electricians in getting the issue sorted. Its amazing what you can do...
  9. T

    Aico Smoke Alarms beeping

    Sorry All, been quite on this thread. Been going through the testing phase. Ok so this is what I've done and so far so good, no damn beeps I went back to the first smoke alarm and disconnected the next in line smoke. The first one was in the loft. I ran this smoke alarm for a few...
  10. T

    Aico Smoke Alarms beeping

    Hi All, Everything is hardwired including the remote, nothing is wireless. Is it worth while disabling the remote to see if that makes a difference i.e. disconnect the remote entirely and feed the two cables into a connector block to test. I will also try Workers suggestion to see if...
  11. T

    Aico Smoke Alarms beeping

    Hi Yes when you use the remote to test, all the alarms go off. When the button is pressed, alarm goes off and you can then silience all alarms expcept the one which is going off. Green light is always on, on all alarms, however you can faintly see a redish/ amber light flash now and again...
  12. T

    Aico Smoke Alarms beeping

    Hi Thanks for getting back to me. The current set up is Smoke, Smoke, Remote, CO2, Smoke, Smoke. All smoke alarms are the Aico EI2110 Multi-Sensors CO2 is Aico EI261EN All alarms have the Hush button The remote is the: Aico EI411H3 Which has the following buttons: TEST - Press to...
  13. T

    Aico Smoke Alarms beeping

    Hi All, Once again, Im back with the same problem. For the last two years Ive lived with the Aico beeping smoke alarms but now is enough. The problem I have the first alarm in the chain constantly beeps at random times. Aico support are useless, spoken to them many times but they...
  14. T

    Aico Smoke Alarms

    Hi All Ok over the weekend I took everything apart and rechecked everything. Starting from the loft which is the first in line, took everything apart, checked the cabling mains coming in and going out to the next alarm. Refed all the wires back into the alarm Switched on the RCBO then...
  15. T

    Aico Smoke Alarms

    HiYa Thanks for getting back to me. Its a dedicated Smoke alarm circuit on its own RCBO 6amp. No lights, just the smoke alarms. I have 3 ei2100 multisensor smoke alarms, Loft, 1st and Ground floor hallway. I have one other in the front porch and I have a CO2 near the boiler...