I have come across a worcester 24i boiler,the problem is the time clock does not keep the time,it does not move.When you have the clock set to manual or auto nothing happens on the central heating.When you turn hot water on the boiler kicks in,gives you hot water and if the central heating is...
one more last thing before i go to bed, can i use fx100/fx400 in the system? if so i think you would have to put them in by the rads is this right or not? good night all.
thanks for all your replies i did think it was a primatic after reading my jtl book but what should i do with the two gate valves? The women tells me she as used the plumber for the last 30 years should i let her know he is not super man like she thinks?If i now change the valves should i get...
I do a few jobs for a decorator i know, i take the rads off the wall when he wants to get to the back of them,and when done i come back.The problem i have is this last job i need to take the rads and change the valves as well but its a back boiler and i cannot found the F&E tank.I can turn the...
thanks for that,now is the diaphragm and the diverter value all in that brass body in the centre of the boiler? all the primary and the hot waterpipe(10mm pipe) run into it.
terry
I have a problem with a ravenheat combi boiler,no manul and i can not get to the badge.The central heating is fine,the hot warter down stairs is good but the upstairs hot water runs hot when first turned on then goes cool and then cold.The boiler runs for about 30 to 40sec and then turns off for...
just to let you know that boiler i went to look at for my mate it had a split control knob for the central heating,got a new knob for the central heating and every thing is great,i told him it was very hard to fix and i got a few pints off him
My friend as a heatline 24/28 condensing boiler.At the moment he as hot water but no central heating,he seems to think its the diverter vale,how do you check the diverter value is working? could it be the sensor on the primary flow?He also says he as a leak some where,he does not think its on...
I have been told over the phone that her boiler,glow-worm fuel saver mark 2 is not firing up when the time clock(randall ndall 702) is asking for heating or hot water.The poilet light is lit ,the lights on the time clock all come on when she as asked the boiler to do something,hot water on...
if i turn off all the other rads apart from the problem two rads they get hot but as soon as i turn one of the up stairs rads on they start to lose heat.I have balance them and i left the job with all the rads being hot apart from the problem two rads which were warm but it was the best they...
the central heating system is a powermax 155x.sealed unit. when running the rads are red hot in the home.the pressure holds at 1.5 bar,no problem.But since they have had a single storey extension done the two rads in the extension(0.900x0.600) got hot when first turned on by the plumber and then...
Hi all,
first of all the job is in a pub, a very old one .all the central heating system is run on the one pipe system blue band steel pipe.the rads are the old cast iron ones.The boiler is a new one and is in the celler.there is a 22mm pipe run from the boiler of no more then 1mt to the 2"...