Recent content by TheBoilerMan

  1. T

    corner toilet

    no probs, get a bent flexible pan connector, it'll do the job.
  2. T

    Chaffoteaux Maury -will work for about 20 mins and then stop

    Suggests its overheating and has to cool before it will relight, check thermistors and that pump is working ok. Otherwise it could well be the PCB. After waitng the 20 mins or so does it then work ok?
  3. T

    powershower pump

    How powerful is the pump? Would have thought it would blow thw the rubber hose off the taps first!! Talk about using a sledgehammer to crack nut!
  4. T

    Water pressure issues

    ooh tony you are a grump!! Do you ever get recommends on charisma alone? TEE HEE just havin a larf!
  5. T

    keston 170

    She does!!
  6. T

    Back in the mists of time - one for all you old C/H experts

    in 1971 there was little in the way of regulation and it could well have been fitted by a glazier or a joiner. It would certainly be illegal today.
  7. T

    time clock ravenheat combi

    Can recommend the Salus RT500RF. Its a 240 volt supply with a volt free switching option. Around £40-60 +vat and a doddle to fit, you only have to remove the 240 volt link on the receiver for it to work volt free. Used loads they are brill and wireless too.
  8. T

    Corgi Certificates & Building Control

    Yes but building control will want to inspect it at far higher cost than corgi. As far as im aware there is no legal requirement on an RGI to issue a certificate. He does however have to inform building control, which in most cases is easiest done by GWN to corgi, who in turn notfy building...
  9. T

    overheating problems!

    Those energysavers were one of the first available condensing boilers and they are notorious for causing sludge in systems. can i take a guess that your system water is bright orange?. suggest you replace it asap or you will be having one problem after another.
  10. T

    vent radiator

    was the combi an upgrade from a conventional open vented system? Check for leaks and get installer back to rectify.
  11. T

    Glow Worm - no-one can fix...

    As said, gas valve solenoid.
  12. T

    keston 170

    definately a 2 boiler job if ever there was one. Vaillant, buderus or worcester.
  13. T

    Water pressure issues

    10/12 minutes to fill a bath :o :o :o Thats a bluddy good combi m8 most take 20/30 min
  14. T

    Ideal Standard Cistern - Float Valve & Quiet Fill Tube

    its probably poor design. expensive sanitary ware with poor fittings, pretty normal considering you get screwed by just about everybody else. Anyway, rant over, go to plumbers merchant and as apb says buy a "Bottom entry torbek quiet fill valve", wont be more than around £17. Job done
  15. T

    anti freeze for central heating systems

    You could always fit a frost stat !!!
Back
Top