    Soffit venting- opinion before they come back in the morning?

    Oh and previously it didn’t have a soffit on, you could see the roof trusses/joists coming out of the brickwork.
  2. T

    Soffit venting- opinion before they come back in the morning?

    Hi all, I’m having new guttering put on and soffit and fascia replaced. The roofer has put a solid soffit on and when I questioned him about ventilation he said that the roofing membrane is breathable so it doesn’t need venting. This is a 2m span next to a bay window on a roof with loft...
  3. T

    Combi dripping from red tap on flow pipe? Pictures

    Yeah that makes sense, just a shame when it’s the actual valve itself fails. Looks like spares are obsolete but a few places showing stock, come as a pack with a few parts in, comes to £155!
  4. T

    Combi dripping from red tap on flow pipe? Pictures

    What does this but do? It looks like it should be a simple joint between the boiler and pipe so why does it need this screwy isolator thing?
  5. T

    Combi dripping from red tap on flow pipe? Pictures

    It’s dry, like Verdi Gris or something. I
  6. T

    Combi dripping from red tap on flow pipe? Pictures

    Yes that joint is covered in green mildew type thing. I can’t see any water coming from anywhere. I’ve put a bucket underneath and will call a plumber in the morning. I’ll keep an eye on the water pressure I guess
  7. T

    Combi dripping from red tap on flow pipe? Pictures

    Hello There’s a slow drip coming from a red tap/isolator thing under my combo boiler, is there a fix for now? It’s an Alpha eco2 plus and looks like it is the flow to the radiators. It doesn’t seem to turn Thanks
  8. T

    Tado wireless smart thermostat to Alpha eco2 plus boiler

    Hello again After fitting a new wireless thermostat to a vokera went well (with a little help from you lot) I thought I’d change the controller and thermostat etc (I dropped it and it’s not been the same since) on my Alpha eco2 plus boiler to a Tado. Bit more complicated than the last one so...
  9. T

    Rust in thermostatic shower filter

    No answers for this one then. The rust can’t be a good sign though. Turns out the cool shower was because the water temperature was turned down to 30 on the remote thermostat, simple really!
  10. T

    Rust in thermostatic shower filter

    Hi I’m having problems with a luke warm thermostatic mixer shower. Here’s what I know- It can be hot for 20 seconds then goes to luke warm and won’t heat again. The taps work fine however take a moment to get hot again after the shower has been used. I have had a pressure valve fitted but not...
  11. T

    Thermostat postioning, everywhere seems wrong!

    Green is the combi boiler, red is a radiator
  12. T

    Thermostat postioning, everywhere seems wrong!

    Hi all I’m fitting a new wireless wall mounted thermostat but reading the advice on where to mount it is just telling me that nowhere available is the right place. It’s a first floor flat with cavity walls and no radiator in the landing. Don’t put it on an outside wall, not near a radiator...
  13. T

    Opentherm mode on Vokera easi heat 25

    Thank you very much Open Therm and this controller satisfy the load compensation criteria then. Thank you for signposting the video, that’s exactly what I needed. Disappointed I didn’t find/skipped over it in my own Vokera and google rabbit hole.
  14. T

    Opentherm mode on Vokera easi heat 25

    I think you’re right by saying it’s not a special mode or anything. Why put the asterisk there? I think maybe it’s just a bit more information to clarify how it meets the requirements.
  15. T

    Opentherm mode on Vokera easi heat 25

    I have seen another flow chart that does seem to suggest only one of the options is needed too, thankfully.