Recent content by tonyramponi

  1. T

    Flappy Soffitt

    Hi, I noticed yesterday that part of the UPVC soffitt at the back of my house was hanging out of the Fascia board. I guess it's been damaged somehow in the recent high winds. I managed to push it back in by standing on the roof of my neighbours extension but the end of the soffitt now flaps...
  2. T

    Damp rafters - no felt

    Hmm, good point on the hot/cold side of the roof. It is the cold side of my roof that is mainly effected. I guess it could still be condensation but there was pretty no sun to warm up anything on the warm side while it was raining so now working on the assumption that it must be penetrating...
  3. T

    Damp rafters - no felt

    Your pictures remind me of my own loft. I've been living in my house for the last 10 years and only noticed after putting Christmas decorations away last year. After it snowed the backs of they tiles were all damp which I felt was probably condensation due to the cold temperatures. I...
  4. T

    subfloor Damp around new water pipe

    Thanks for the response. I had a bit of a prod around and the ducting ends just below the surface so the pipe is exposed where i'll be putting the cement. Yep, its a suspended floor. I have the same thought that the topsoil is an easier path for the damp.
  5. T

    subfloor Damp around new water pipe

    I recently had a lead water supply pipe replaced in my 1930's Semi with a MDPE pipe. While running an electrical cable I've had the floor back up and noticed that the sub-floor around the pipe entry is damp. The subfloor doesn't appear to be damp elsewhere - Just around the new pipe: - I...
  6. T

    Biasi Boiler Prisima 24se Hot water problem

    A cryptic response from a man in the know! If no parts are required then I guess something either needs cleaning or has gone out of adjustment. I would guess something to do with the gas valve, it looks like it could be a new one as it has the part number written on it in permanent marker -...
  7. T

    Biasi Boiler Prisima 24se Hot water problem

    Thanks, I'll look at that first. What causes the boiler to cut out when theres a plate exchanger problem? Is it something to do with the temperature differential between the two temp sensors?
  8. T

    Biasi Boiler Prisima 24se Hot water problem

    Hi, My Biasi boiler (24se model dated 1997) has developed a problem whereby it keeps switching on/off in 10 second cycles while in DHW mode. CH is fine. It only appears to be the flame/gas which is being switched off, the fan keeps running and the voltage stays on to the pump which leads me...