    Ideal Elan 50NF boiler problem

    Thanks to all but after some extensive searching tonight, I've managed to not only track down the SIT part no for the solenoid but have also found a site that sells them. Happy days......
  2. W

    Ideal Elan 50NF boiler problem

    The valve is a SIT-830 Tandem part no. 0830020. Both solenoids come in one unit which simply bolts onto the side of the valve itself.
  3. W

    Ideal Elan 50NF boiler problem

    Thanks very much. Yep, EV1 is open circuit. Phoned round a couple of suppliers and it turns out that you can't replace the solenoids, the whole valve has to be replaced!. They're not too expensive at about £70 but really - total valve replacement for the sake of a faulty coil. Paul
  4. W

    Ideal Elan 50NF boiler problem

    Hello, I have an Ideal Elan 50NF boiler that won't light the pilot light. Its electronic ignition, it sparks fine, fan and pressure switch work but there is no gas at the pilot light. There is 240v on the red lead to the gas solenoid when switched on so I've come to the conclusion that the...