  1. X

    Nailed on first layer roofing felt

    Garage and is already tounge n groove, and in good con, so need to replace
  2. X

    Nailed on first layer roofing felt

    It says nail the felt on a tounge n groove roof, first layer only On say a plywood you would not. Is perfrorated always need as a forst layer regards
  3. X

    Nailed on first layer roofing felt

    On a tounge n groove deck, why would you nail or just do a tack coat of hot bitumen as opposed to a full layer of bitumen as you would on a plywood deck? Is it so the bitumen does not get into the grooves, and room below, or somthing else
  4. X

    Coldseal roofing v Torch on

    I read you use a paste? were the green min felt joins, then cut the accesss bitumen awey, the bit that comes out the side from heating up cheers
  5. X

    Coldseal roofing v Torch on

    One more thought :D Say the drips are on, cap sheet ready to go down, Measure, cut, water wash down the side, heat cap sheet, and cut access fron the egde, If i have it right? cheers
  6. X

    Coldseal roofing v Torch on

    :D Thanks bendy, my brain may ache when i put all this into practise
  7. X

    Bitumen on a appliance

    Ie washer, Whats the best way to shift, white sprits :?: regards
  8. X

    Coldseal roofing v Torch on

    Does torch on drips, seal to torch on cap sheet, if they both are green min felt? Is torch on safe to use on a timber deck? Are the drips formed, by nail to timber batton, fold, torch to fold, and torch to cap sheet? cheers
  9. X

    Coldseal roofing v Torch on

    Cheers, Are the drips formed the same way, as the hot bitumen method with torch on? But were the hot would go, the torch goes? Any rec on torch on felts, I have looked at the rubberoid site, seems ok Do you use perforated on timber, first layer, I was thinking 2 or 3 layers, Mabye finish...
  10. X

    Coldseal roofing v Torch on

    I want to do a garage, with either one of the above Are the drips easy to do with torch on, do you use a hand held small torch? Any ideas about the drips on coldseal? And anyone used the above, any help, or advice would be welcome I do fancy the coldseal method.
  11. X

    Shed roof

    Must be the felt then letting water in someway, just seems as if the felt is dry though, suppose its a few yrs old now cheers
  12. X

    Shed roof

    In the middle, the tounge n groove boards are rotten, the felt seemed ok, Heavy duty green mineral, I ripped some on top to have a feel, as i will replace anyway The top boards are rotten as well, would that just be the felt causing the prob?