Hi i am installing a bathroom suite next week for college work.
I am doing it at a friends house they have an electric shower now but they want a thermostsic bar mixer.
They dont have a combi they have a cold water cistern in the attic and hot waer tank in airing cupboard next to it.
I told...
Hi i have been asked to change a shower from one wall to another the current shower is electric.. But they want a new thermostatic shower or electric one. Would it be easier to fit electric one and get electrician to install the electric part as it is moveing further away from consumer unit. Or...
Hi i have been asked to change cast iron down pipe/rainwater pipe to plastic as it is leaking but the guttering is staying as cast iron can this be done?
or do you have to change guttering to plastic if it can be done is there are a special connection to put plastic down pipe into cast iron...
Thanks for all the advice
The college are a joke to be honest we have had 3 different teachers in this time.
The course is the nvq level 2 plumbing and heating.It is not the apprentice one.
It is 2 nights a week but to get the full nvq level 2 this is appently what we have to do.
I would...
Hi i am coming to an end of my 3 years at college.
I have just been told if i want my full nvq lev2 I have to get public liability insurance and do 2 jobs why teacher comes out to the job.
I have also been told i need to go self employed and start a business to do this.
Only thing is I...
Hi not sure if my pic has posted but the problem is my combi keeps losing pressure other a couple of days.
After looking everywhere i have found the drip it is underneath the combi on the return pipe right at the top where the 22mm pipe meets a big fitting(don't no what it is called) but it has...
Hi i have a 2 bed house with 4 rads and 1 towel rad. I have just bought a new rad to put in spare room as there isnt one in there.
In this room is my combi worcester 240
My question is can i connect directly onto flow and return on combi as new rad will be on the same wall as it and if i try...
Cheers
So this means you cant add on to any pipework within these 3 areas.
If i wanted to add on a rad do i just t into 1 of the rads allready in the house
Just a quick question.
In college today we where told you cant add on pipework for new rads at certain parts of the pipework.
Teacher said 3 parts you cant add on to and these where called the 3 ts...Could anyone explain abit more to me where and where not your allowed to add rads on
thanks
Hi i am not too good with computers but i am trying to send my cv out to companies but I dont have microsoft word and they keep asking for it.
Is there any where i can down load it from if not how much does it cost
any advice will help