Search results

  1. J

    Tree assessment reports

    Hi Nakajo, They don't and I don't. Outside of the planning process, I can chop down the trees with impunity. But as the trees are currently there, they are saying we need a report to get through the planning process. I live in Bristol and local planning policy says that the overall tree canopy...
  2. J

    Tree assessment reports

    Hi, I am not sure if this is just a rant or a request for advice ..! I have a semi derelict 1920s garage in my garden that I would like to knock down and replace with a garden room and storage area. The details aren't important; it is unambiguously a scheme that needs planning permission...
  3. J

    OSMO MS Advance glue any good?

    Hi, I need to lay about 24 square metres of solid oak parquet to a concrete slab floor. The slab was laid about 10 years ago, with a DPM, and has wet underfloor heating installed. It's been 'pretty well' levelled with a water based self levelling compound (TileMaster Rapid Level 30) to no more...
  4. J

    Floor levelling/priming recommendations

    Hi, I've scanned the forum and can't see an exact answer, so apologies if I'm duplicating stuff that's been covered before. I have a 6 metre x 4 metre kitchen concrete slab floor in my kitchen. It's ten years old so modern standards - well insulated, damp proofed. It has wet underfloor...
  5. J

    Cable in insulated ceiling void

    Indeed, I was. Hopefully the context in which I used it is clear to you and goes some way to explaining to you why I did so. I fear that this thread is veering away from sensible discussion about electrical matters, so this is now the last post from me. As before, thank you for your help and I...
  6. J

    Cable in insulated ceiling void

    Hi John, Thanks for the reply. You are right to call out 'SWMBO' generally; it's an artefact of misogyny, best left in the middle of the last century with mother-in-law jokes and anything related to Jim Davidson. In my case, as I am sure you see, the use is consciously and intentionally...
  7. J

    Cable in insulated ceiling void

    Dear John, You know nothing about me, my partner, our relationship, or our mutual humour. But, still, you feel free to pass judgement if it makes you feel better. Keyboard warriors like you do, after all, make the world a better place. Just rest assured that your sense of grating is all your...
  8. J

    Cable in insulated ceiling void

    It'll never catch on.
  9. J

    Cable in insulated ceiling void

    Thanks both. I have to say, having now spent the best part of a day scissoring some slightly springy joists and fitting the stuff, the 'chatter chatter', bang-the-cupboard door and rattle the cutlery tests tell me that the acoustic insulation has made less than bu66er all difference. Still, I...
  10. J

    Cable in insulated ceiling void

    Hi, SWMBO has deemed that we should stuff the floor joists to our kitchen ceiling with 100mm of *acoustic* insulation (so kitchen chit chat doesn't get overheard in the bedroom above) before we put new plasterboard on. The joists are ~240mm deep and various lighting and socket cables are...
  11. J

    Cutting bricks flush to existing brickwork

    Thanks @^woody^ I am notoriously limp wristed, so was hoping for a solution that used electricity. But, I'll try the bolster chisel for a bit before having a little cwy. Dust isn't really an issue. When I say "kitchen" I actually mean a room stripped back to bare walls with a taped up door.
  12. J

    Cutting bricks flush to existing brickwork

    Hi all, I have an Edwardian brick chimney in my kitchen. I want to create a squared-up opening in it. The brickwork in the body of the chimney starts to form the throat of the chimney below the height at which I want to square the opening up. I have had formal calculations done and inserted...
  13. J

    Splitting 10mm cable for multiple ovens

    Thanks. I'm not trying to be deliberately obtuse (just trying to understand) but ... Ok, get it. The devices cannot cause any sort of overload. But, short circuit. If the fault current is likely to be 100s of amps, why are you suggesting I swap the RCBO for a 32amp one and/or why is John...
  14. J

    Splitting 10mm cable for multiple ovens

    Hi John, Thanks for the post. I am clearly not a spark so excuse the dumb question, but if 2.5mm cable is rated to 27A maximum, I don't understand how a 32A RCBO would (and a 45A RCBO probably would) protect it from a short circuit induced high load? Is this the "can withstand approx. 1.5 x...
  15. J

    Splitting 10mm cable for multiple ovens

    If I were perverse, for reasons I can't think of right now, and insisted on keeping the 45A RCBO would using 4mm cable for the links to each appliance be better than using 2.5mm? Thanks, again, for your help.
  16. J

    Splitting 10mm cable for multiple ovens

    Rationally, nothing, I guess. Just feels a bit messy but I guess it's what everyone else does.
  17. J

    Splitting 10mm cable for multiple ovens

    @EFLImpudence - Thanks for the reply. I guess I am struggling to find a junction box that isn't some sort of surface mounted monstrosity that will take a 10mm cable and 5 or so 2.5mm cables! If I don't fuse down when I break the 10mm cable into multiple 2.5mm cables before I get to the...
  18. J

    Splitting 10mm cable for multiple ovens

    Hi, I have a 10mm cable, fed from a dedicated 45 RCBO in my consumer unit, feeding my current range cooker. Everything (mains incomer, consumer unit, all internal wiring) done in 2012. SWMBO has redesigned the kitchen. She has ordained that we shall have a 16 amp rated oven; a separate 13 amp...
  19. J

    Steels bearing on wall above door frame

    Hi, Thanks for all of the replies above. (1) Whatever the rights and wrongs of the '45 degree spread of the load', it's a bit of a moot point. The beams are steels are roughly central above the door frame and that's roughly a square area of brickwork above the door frame too. So, one way or...
  20. J

    Steels bearing on wall above door frame

    Hi, We've taken down our kitchen ceiling and think we've found the root cause of something. Our house is Edwardian. Resting on the wall above our kitchen doorway is these two steels. They're supporting a single skin, single storey, internal brick wall above (about 4m long x 2.4m high). For...
Back
Top