Search results

  1. J

    Flat expansion vessel

    What was the pressure this morning when you fired up the boiler?, check it again in the morning before firing the boiler.
  2. J

    Flat expansion vessel

    Unlikely, but possibly one or both filling valves left open. What is the boiler pressure now now and is the system hot or cold and is CH on or off?.
  3. J

    Thermostat not switching off boiler

    Correct, I got mixed up with the switched live colour of blue.... so 230V constant between the brown and the blue (N) on the left, irrespective of the stat setting, and 230V between the switched live, blue on the right and blue (N) on the left with the stat calling for heat and 0V when not...
  4. J

    Thermostat not switching off boiler

    If you can use a M.meter, check for 230V between the brown and the blue on the far right, ter 2, while turning the dial up and down.
  5. J

    Anyone measured how much gas or oil used to heat DHW with the central heating?

    I remember over sink instant (I think) gas fired water heaters where the gas fired up as soon as you opened the hot "tap"?.
  6. J

    Immersion failing

    Q Is that likely though, with a side mounted unit??.
  7. J

    Changed radiator now F&E Tank is overflowing

    Strange though why changing a rad should affect the static level in the F&E cistern
  8. J

    Immersion failing

    I've seen postings where incoloy immersions but with copper pockets do fail (leaking pocket) in less than 6 months, when used in stainless cylinders, its suggested to ensure that the pocket also is incoloy, apparently some are not.
  9. J

    Immersion failing

    You're correct, the only way I can see that pocket/tube failing is either mechanically, maybe (but very unlikely), fouling on something inside the cylinder or very acidic water corroding it but most unlikely in a matter of a few months. You might hold on to this one when you remove it and take a...
  10. J

    Changed radiator now F&E Tank is overflowing

    Yes, that should be OK, CC2 at 5.1M, but would probably work fine on CC1 at 4.2M, one green only.
  11. J

    Immersion failing

    Can you post a photo of any one of the failed immersions after removal concentrating on the pocket that the thermostat rod is inserted in, showing any visible signs of corrosion, cracking, etc. Have you, as suggested in your other thread, tried a Becker Immersion??
  12. J

    Thermostat not switching off boiler

    Assuming two new stats, if you turn one off on its on/off switch as shown, and the other (the one you say isn't working normally) doesn't switch off the boiler off "normally" and you then switch that off also, see does it shut down the boiler. If it does, leave it switched off, turn on the other...
  13. J

    Changed radiator now F&E Tank is overflowing

    Not sure what you mean by setting it back to III, the only "III" above is constant curve III, IF it was on this setting then would/could definitely cause problems, if now set to PPI then too low IMO. Based on my own 12 rads I reckon that you require around 3.3M to give a flowrate of 20LPM if...
  14. J

    Changed radiator now F&E Tank is overflowing

    You said in post #6......"Three LEDs, when firing the I is green, II and III are amber." If it is Green space space yellow then I think it should be flashing, I think all the PP & CP settings have flashing LEDs but maybe thats only while configurating it, its a long time now since I set a UPS3...
  15. J

    Noisy Cylinder Continuing Saga - Help Wanted!

    Can you post a photo of the external? Grundfos Pump while running. showing the LEDs, also show/state its model number. OK, I see you have a internal pump. EDIT. it shows a external pump in the WB MIs but you stated in another thread in reply to my same query (re internal or external) that its...
  16. J

    Is a 'water hammer,' always an indication of a problem?

    Just lift the top off and you should see something like mine, downstairs as well with the Flomasta type filler, if the filling part is offset like mine then should be OK to install the ballcock type, take a snapshot of the inside of the cistern and show it to the plumpers supplier. I installed a...
  17. J

    Changed radiator now F&E Tank is overflowing

    Assuming a max of 120L rads+system, the max expansion vol will be 2.5L when fully hot, my 30L F&E cistern, LxBxH, 381mmx254mmx305mm will rise by 10.4mm/liter so 2.5L will cause a rise of 26mm, say just over a inch, not a lot, depends obviously on the cistern dimensions, measure your own.
  18. J

    Changed radiator now F&E Tank is overflowing

    Under really no circumstances should you require that UPS3, a giant of a pump, on its max setting of CC3, which, in effect is a constant head of 6.4M up to over 19.0LPM, I'm surprised you're not getting even more carry over and air ingress, CC1, at over 4M should be adequate, one green, if not...
  19. J

    Changed radiator now F&E Tank is overflowing

    Gas or oil boiler/ Internal or external circ pump? If external, post make/model/mode/setting or/and a post of any LEDs when running.
Back
Top