  1. J

    Central heating system blowing fuses

    can you isolate the system and leave just the timer connected, try taking out the cables to the heating and the hot water one at a time and or both at once. hope this makes sense as I am a electrician not a plumber
  2. J

    Memera 2000 Consumer Unit

    I dont think you can get those 'white' MCBs but Im 100% sure that you can get newer MEM MCBs which fit in to those dbs...
  3. J

    HF Intermittent lights

    Make sure your switch is x-rated I think it means that it is suitable to use in a commercial environment where you would have lots of fluorescent lights.
  4. J

    Spot the mistake

    this where the cables go. how many blue cables are there?
  5. J

    Spot the mistake

    have a look on the left of the picture, see where the blue cables go into
  6. J

    Spot the mistake

    Was carring out a PIR today and I came across this and other faults hope the picture shows properly
  7. J

    Best way to wire plinth and kitchen cabinet lights

    thought I was still at work typing out test forms :oops:
  8. J

    How old are these and suggestions for what to do with them

    There is a wholesalers in/near Ipswich which has stuff like that on display
  9. J

    Best way to wire plinth and kitchen cabinet lights

    I refited my kitchen a few years ago,we have one centre lgt plinth lgts (not yet fitted) and under cupboard lgts. The 3 sets of lgts are fed from a 3gang switch, where I have the Live and Neutral in and then the Live and neutral out to the 3 sets of lgts
  10. J

    4mm2 HO5 RR-F

    4mm flex just use 6mm twin ...
  11. J

    4mm2 HO5 RR-F

    is it 4mm heat resistant twin or 'flex'
  12. J

    Multiple "shaver" sockets

    I like mk grids but you can see that wont last more than10 mins if used!! Just buy a normal 2g shaver skt
  13. J

    Questions on installation and inspection forms.

    A pir is like a MOT there are many things you can not get to, im sure there is a paragraph to say cables under floors etc etc. For the dno fuses we write no access, for some commercial installations you can not even see the cut out fuses. when I worked on social housing I was told to always...
  14. J

    Help :applying to be a apprentice electrician

    Yes I got on the training scheme, found a job and went to college (day release). If everything goes right, it takes 4 years to become an electrician, I have been qualified since 2000ish and work for a national company.
  15. J

    Help :applying to be a apprentice electrician

    When I left school the careers adviser put me in touch with the JTL, they manage apprentices. Have a look on their website, Im sure they will be able to help http://www.jtltraining.com/youngpeople/home.php
  16. J

    will this light fitting be enough for our bathroom?

    We have a 28w 2d fitting with a opal diffuser in our bathroom, about 2.6mx2m, it gives out more than enough lgt.
  17. J

    LIMs/Schedules of Inspections

    when you go to the db take switches off, etc you can see what cables are used, and see if they have any 'Cables incorporating earthed armour or sheath, or run within an earthed wiring system or otherwise protected against nails, screws etc... '. also when you take of switches/sockets you...
  18. J

    3 Core SWA earthing

    If possible I allways bond the banjos at both ends
  19. J

    Potterton Profile 40e

    I know it proberly won't help you but they were made between 1988 and 2001. My dad used to work at the factory where they were made.
  20. J

    Replacing Pull Switches

    check how many terminals you have at each switch, old and new, your old switches if they have four terminals might be double pole switches, if your new switches have three terminals, they mght be two way switches.