Search results

  1. RainTown

    Radiator Sludge

    just short update. The original installer still ignoring me. Baxi support will kindly send one of their own engineers to check the installation. For private reasons this will be a few weeks from now. IF they identify any faults, they will then advise how to proceed. They confirmed that...
  2. RainTown

    Radiator Sludge

    I had 5 radiators TBOE connected though, which the installer knew and knows, as he reconnected all of them after removing them all from the property and emptying them down the nearest drain. And he was told again this week, and still maintains, as insistently as you do here, that it does not...
  3. RainTown

    Radiator Sludge

    Luckily for who? This is the bleak part that I am discovering, little more than theatre, a sham - poorly regulated, patchy (at best) enforcement, and in practice a consumer has very little redress.
  4. RainTown

    Radiator Sludge

    Recapping a bit, I bought a new Baxi boiler, to replace an old Vokera boiler. The installer had visited and seen the property / setup in advance, and quoted for Baxi supply and installation, relocating the boiler approx 60cm to the left within the same room, and adding some Hive TRVs to the...
  5. RainTown

    Radiator Sludge

    Based on my experience here I agree. If competent work by a qualified professional depends on the customer acquiring near-professional knowledge, drafting detailed specifications, and supervising execution, it's a pretty bleak world - we are talking here about installing a boiler, not building a...
  6. RainTown

    Radiator Sludge

    No, I am not reluctant. IMO I am opposite in fact, I am eager to learn new things. But "facts:" have a higher bar than, respectfully, denso13 wrote so in a forum post. Nonetheless, point taken, I will check this with Baxi Support. (There's little point me asking the installer, as I would...
  7. RainTown

    Radiator Sludge

    Again, thanks for all input, and the correction on hard/soft water in Scotland part. The original boiler install guys were supposed to come earlier in the week, not unsurprisingly they didn't show up. A couple of quotes from recent posts: "You need to find a better quality of...
  8. RainTown

    Radiator Sludge

    Yes, Glasgow is typically considered a hard water area. As regards a filter, Harry wrote: “It is a requirement, rather than an option” Gas Safe guy didn’t mention it, the 2 British Gas services of the Baxi boiler didn’t mention it. One of the power-flush plumbers did say he’d add a filter...
  9. RainTown

    Radiator Sludge

    Well, there was no filter before and I didn’t ask for one. They quoted for supplying and installing (including relocating) the Baxi 430 combi boiler and fitting the new TRVs, and decommissioning old boiler. That’s what they did. Probably including the flow/return mistake.
  10. RainTown

    Radiator Sludge

    Thanks. I’m actually active on helping people on a few IT forums, and it’s exactly the same - if I could see their screen for 10 minutes the problem would be often teadily identified. But of course they describe the inputs and outputs they get from what is effectively a black box to them, and...
  11. RainTown

    Radiator Sludge

    Yes, this seems to my conclusion too. Here’s my logic: The left most pipe in the Baxi 430 Combi right now is the CH Flow, both from the product documentation and simple physical check - when it starts up that pipe gets hot first. That leftmost pipe was also the leftmost pipe when the Volkera...
  12. RainTown

    Radiator Sludge

    That’s the before picture, the previous Volkera Compact 24 Boiler. All 6 pipes went straight down vertically under the floor. All were cut above floor level and rerouted to the new boiler. I’ve fotos of the “after” so I should be able to map those 6 pipes to the current connections on the new...
  13. RainTown

    Radiator Sludge

    I’m not questioning the plumbing aspect. In an earlier post, someone else advised me to go to local plumbers merchant, get their recommendation. Seemed good advice. That’s precisely what I did. That recommended guy has written “as you know a flush might help the situation”, confirming what he...
  14. RainTown

    Radiator Sludge

    No, in fairness he meant roughly same price as power flush. He’d already dismissed the importance of flow/return possibly being wrong way around. Unfortunately I just cannot do it myself. I’m partially sighted. I can just about see well enough , in good light, to get a spanner around the lock...
  15. RainTown

    Radiator Sludge

    Thank you. Yes in all cases lockshiekd is at the bottom. And in most (5/6) cases the TRV is at the top.and there is differing levels of OK-ness , or otherwise, across those 5. The one with both at bottom works best. I will double check all of this later. Of course can’t know with...
  16. RainTown

    Radiator Sludge

    This is what I assumed. And that “gets hot first” connection is consistently at the lockshield. And without being able to say 100%, I think it was always so. Pre Baxi too.
  17. RainTown

    Radiator Sludge

    I hoped a Gas Safe registered installer, also on the approved list from Baxi , would be better. They actually were very tidy, and took old boiler away. They didn’t go to the pub, but they had a train to catch. The 3:15 from Glasgow Central. Left my place 2:35 or so.
  18. RainTown

    Radiator Sludge

    It’s a seek thermal attachment to my old iPhone. Seek Thermal Compact XR Extended Range Thermal Imaging Camera with Lightning Connector and Protective Waterproof Case for Apple iOS Devices - Black Cost me 180 quid from Amazon in 2017. I lost track of it, and only found it in a box of cables a...
  19. RainTown

    Radiator Sludge

    Sorry, practically, how to know? 95% of the piping is under tbe floor. Is that something the customer should be checking after a new boiler was installed and new TRVs fitted to all radiators? Really? Remember around 8 different plumbers/ gas/installers have looked at it over last 3 years or so...
  20. RainTown

    Radiator Sludge

    Ok, so if I am understanding correctly, there’s now a new theory, it’s just setup wrong? The old boiler certainly worked the radiators better, but as I didn’t live there I can’t really quantify this claim. And it was years ago. The boiler was relocated when the Baxi was installed, about 60cm...