  1. Risteard

    2 Lamps to 1 Mains Plug

    Then you shouldn't be carrying out In-service Inspection and Testing of Electrical Equipment.
  2. Risteard

    2 Lamps to 1 Mains Plug

    It is impermissible.
  3. Risteard

    2 Lamps to 1 Mains Plug

    By definition it can't have been done correctly, as it is incorrect.
  4. Risteard

    2 Lamps to 1 Mains Plug

    As above.
  5. Risteard

    2 Lamps to 1 Mains Plug

    I clearly disputed the claim that "it shouldn't be a problem." It categorically is a problem.
  6. Risteard

    2 Lamps to 1 Mains Plug

    Incorrect.
  7. Risteard

    Thin singles for steel conduit

    The south of Ireland does not permit 1mm^2 conductors in fixed wiring.
  8. Risteard

    New CU installed, right type RCBO for EV?

    I have installed hundreds (including for OLEV/OZEV and SEAI grant eligible installations) - all correctly. I even drive an electric van myself.
  9. Risteard

    New CU installed, right type RCBO for EV?

    The RCD MUST interrupt all live conductors. Also, a 40A device is much more appropriate than a 32A.
  10. Risteard

    Thin singles for steel conduit

    I'm not obliged to read through all the gibberish posted here.
  11. Risteard

    Thin singles for steel conduit

    It isn't. That would be 2-way and Off.
  12. Risteard

    Thin singles for steel conduit

    No, I didn't assume that he was American. I simply sought clarification as to what exactly he meant by a "3-way" switch, given that no such thing exists. It's not difficult to understand, unless you are intellectually challenged.
  13. Risteard

    Thin singles for steel conduit

    That's precisely what the Americans call an intermediate, so it was a fair assumption.
  14. Risteard

    Thin singles for steel conduit

    Thankfully I don't need to try. I was born clever.
  15. Risteard

    Thin singles for steel conduit

    It wasn't clear at all to me. I wasn't sure whether he was referring to an intermediate switch or otherwise
  16. Risteard

    Thin singles for steel conduit

    What is a three way switch?
  17. Risteard

    On / Off Neon Switch

    LAP is garbage.
  18. Risteard

    Consumer Unit Height (Guidance or Punishment by Death)

    How so? Every kitchen has presses.
  19. Risteard

    Consumer Unit Height (Guidance or Punishment by Death)

    It doesn't mean in a kitchen press where you have to balance on top of a fridge.
  20. Risteard

    Consumer Unit Height (Guidance or Punishment by Death)

    A good firing squad can deal with multiple condemned.