  1. D

    Poor pressure from new shower

    If your hot is restricted flow then blanking the cold and testing the hot on its own would have shown this
  2. D

    Heating not going off on timer

    Do you have a blue light on the boiler?
  3. D

    Showers gone luke warm?

    No they are tank fed
  4. D

    upstairs bathroom existing soil pipe alteration advice

    You can get a slip socket (or grind the stops out of an ordinary push-fit socket). This will slide all the way on to 1 section, then line up the other section and slide to be half & half. I usually fit a clip below to make sure it can not slide down. Also handy to get a clip to support so that...
  5. D

    Showers gone luke warm?

    Do you have other hot taps supplied by this cylinder and if so do they run OK? Could a bit of fibreglass etc have got in to the tank? Could you disconnect one of the hot pipes and put a hose on it and confirm that full flow is available on the hot? Drop shower head in to tray and run shower...
  6. D

    Insufficient flow Hot Water from Unvented Cylinder

    The hot water outlet from the cylinder can get quite choked so worth a look in there
  7. D

    Poor pressure from new shower

    Was this at hot and at cold individually or simultaneously or was only cold tested ?
  8. D

    Heating not going off on timer

    Power off. Put link from L to w.on and from w.on to h. on. Power back on room stat and cyl stat up valve should be mid position, pump & boiler running, rads & water heating. Turn cyl stat down, valve should be H, pump & boiler on & rads heating Turn cyl stat up & room stat down, valve should be...
  9. D

    upstairs bathroom existing soil pipe alteration advice

    Where the waste is (was) connected in to the soil pipe, the fitting on the end of the waste pipe is a boss adaptor which should be glued in to a pre-formed boss on the branch. Yours has been glued in to a hole cut in the side of the branch, no good at all. I would now describe that branch as...
  10. D

    Showers gone luke warm?

    OK got it. Senior moment
  11. D

    Showers gone luke warm?

    He has checked and hot pipe at shower is "very hot"
  12. D

    Showers gone luke warm?

    You did clean the correct filters? There are 2 pairs of filters for different inlet configurations. Only 1 pair is in use
  13. D

    Heating not going off on timer

    Have you put the clock back on?
  14. D

    Boiler losing pressure every day, replaced PRV, Gauge not showing high pressure

    You have checked the gauge so it isn't lying It could be a bit of muck on the seat of the valve so if you fully open it it may wash off Let it snap shut as well rather than slowly shut. Only a vague chance of this working but is always worth trying
  15. D

    Low mains water pressure

    What about the cold water? You have a combi so hot is dictated by that. Drawing 2 baths at once is going to be pathetic off a combi so "dribbling" is a bit subjective. Flomate 60 will deliver 12l min continuously, this is of course hot & cold and not sure what the maximum pressure is that you...
  16. D

    Heating not going off on timer

    Let me know how you get on.
  17. D

    Heating not going off on timer

    Well, you had jumped ahead a bit as I said. Not sure where you are now with clock on or of so suggest you do as above. Have a look at the boiler because if you turned the power off while boiler was running it may have gone out on overheat. This is what the pump over run prevents. What boiler is...