Search results

  1. P

    Aico alarm wiring instructions

    I would not bet on the pictures on amazon being accurate. 4-core flex with a blue conductor certainly exists, I have some in my garage that I *think* came out of a maplin offcuts bag bought sometime in the 1990s or early 2000s. However since grey conductors became a thing in the mid 200s...
  2. P

    Aico alarm wiring instructions

    I recall reistard claiming that oversleeving a line-coloured conductor to use as a neutral was not permitted in the republic of ireland. If-so that would presumably mean a special cable type was needed.
  3. P

    Blanki g cooker isolation under sink to pass EICR

    No, it's collecting stuff from the internet, using that stuff to generate model weights and using those model weights to come up with confident, plausible-sounding answers. This process is quite capable of generating new bullshit that did not come from any human.
  4. P

    Connecting replacement cable, for hob circuit, into old Consumer Unit with shared RCD - 'legal' (within regulations) or not; notifiable or not?

    IIRC there is a regulation in BS7671 about dividing an installation into circuits to "avoid danger and minimise inconviniance". IIRC in older editions of BS7671 this regulation didn't explicitly mention RCDs, in newer editions it does. Given that in my experiance RCD trips are about as common...
  5. P

    Are these C2s or C3s

    Conversely, the presence of thermal damage to bonding conductors would be a massive alarm bell.
  6. P

    Are these C2s or C3s

    Bonding conductors can carry two types of current. The first is "fault currents", a fault happens somewhere and some proportion of the fault current flows through the bonding system. IIRC in a domestic/light commercial setting, a 6mm² bonding conductor will almost-certainly be enough to handle...
  7. P

    2 kWh battery pack, is it permitted, is it safe, and is it worthwhile.

    There is clearly the risk that such a device will increase the time from a fault being detected by a RCD to the power being shut down. Particularly in the case of single pole RCBOs. Double pole RCDs/RCBOs mitigate this somewhat but ideally an inverter would not be on the same RCD as any...
  8. P

    Are these C2s or C3s

    The sad fact is there are few cast-iron rules on coding, there is lots of industry guidance but industry guidance is not the law, it's not even BS7671. BS7671 says something along the lines of "installations designed to previous versions of this standard are not necessarily unsafe for continued...
  9. P

    BT phone line/service 'upgrade'

    Given the headline says "Make unlimited calls to UK landlines and mobiles with our optional Calls service. " and their FAQ also says they exclude "premium rate" numbers I'd guess they don't want to be bothered with per-minuite phone billing. As well as the technical complexity, IIRC there are...
  10. P

    BT phone line/service 'upgrade'

    FTTC and FTTP and dedicated fiber services share the same cables from the exchange to the aggregation node. Beyond that the three systems use seperate cables (though they will almost certainly share ducts and poles). I'm 99% sure that the aggregation nodes were built with FTTP in mind, even...
  11. P

    BT phone line/service 'upgrade'

    Yup Afaict there are four parts to an openreach FTTP connection, exchange to aggreation node, aggregation node to splitter, splitter to DP and DP to customer. Exchange to aggregation node was built out as part of the FTTC rollout. Aggregation node to splitter node to DP is normally built out...
  12. P

    BT phone line/service 'upgrade'

    Doesn't entirely surpise me. I suspect BT retail assumes that normal residential customers buy their phone and broadband as a bundle. For phone/broadband customers the main way to "encourage" customers to switch seems to have been offering them new deals. and burying in the fine print of those...
  13. P

    BT phone line/service 'upgrade'

    The cables from the exchanges to the aggregation nodes are used by both FTTC and FTTP. The cables from the PCP cabinet to the customer are, for the most part, existing cables from the pre-fiber era. That leaves the cables from the aggregation nodes to the FTTC cabinets, the fiber cabinets...
  14. P

    BT phone line/service 'upgrade'

    Openreach FTTP is based on GPON. I can't find any specific numbers for openreach's network but a general search suggests that GPON has a specified range limit of 20km but that many communication providers limit it to 16km for reliability. That compares to a max of about 6km for ADSL (and the...
  15. P

    BT phone line/service 'upgrade'

    I think I found the answer, thanks to a search term provided by bernard. https://www.ispreview.co.uk/index.php/2025/09/openreach-launches-alternative-uk-analogue-phone-line-product.html I would assume this is what you were migrated to. A VOIP product with the analog <-> VOIP trainsition...
  16. P

    BT phone line/service 'upgrade'

    Yes, absense of power in cabinets is not a problem for openreach FTTP. Power is only required at the telephone exchange and customer premesis. (this does not nessacerally apply to non-openreach networks, I'm aware of at least one altnet that does use active cabinets for FTTP)
  17. P

    BT phone line/service 'upgrade'

    As I have said before, FTTP does not use cabinets. FTTC goes from a telephone exchange to an "aggregation node" to a "FTTC cabinet" to a "PCP cabinet" to a "DP" to a customer. The aggregation node PCP cabinet and DP are passive, but the FTTC cabinet is active. FTTP goes from the telephone...
  18. P

    BT phone line/service 'upgrade'

    The internet is just a network of networks, if your service provider and your VOIP provider are the same company then the VOIP traffic need never leave your provider's network. This can mean they can offer higher reliability than if you use VOIP over the open internet. It's perfectly possible...
  19. P

    BT phone line/service 'upgrade'

    It requires a data connection to the VOIP provider, not nessacerally an internet connection.
  20. P

    Cable size and diversity

    Afaict it's not practical to build an induction hob where the actual induction part runs at 50Hz, a much higher frequency is needed for effective heating. So an induction hob is an electronic load, and it's voltage/current characteristics will depend entirely on how the control electronics behave.