    Melted shower cable - loose connection?

    Go with a decent brand of switch, check cable size against load etc also.
  2. R

    Yesterdays Job

    Dynamite will cure that.
  3. R

    Should We Be Worried?

    It's not like the electricity meter bypass trick, you can't just tap into a fibre optic cable.
  4. R

    Optima compact beep warning sounder

    The unused zones will need to be programmed as not used, or the zone(s) physically shorted out in the panel.
  5. R

    Help engineer code needed

    Why do the installers 'lock' the system, it's the customers not theirs. Anyway enough about two bit electricians doing stuff that only security guys should do!....and usually getting it totally wrong. As Sparkymarka, there are documented ways to get around NVM locks, these involve shorting out...
  6. R

    Telecom Veritas 8 weird problem

    I think it's press and release the tamper spring 3 or so times on power up to fully default the system IIRC.
  7. R

    Is Screwfix forum down today?

    TBH I very rarely post, since they stopped private messages it became very hard to offer personal advice out of the glare of the public eye, which a lot of people preferred. I primarily lurk these day unfortunately. Also, and the main reason I suppose, was the blatant admin misuse of banning etc...
  8. R

    Is Screwfix forum down today?

    I am indeed mate.
  9. R

    Is Screwfix forum down today?

    Agreed.
  10. R

    Texecom Premier Elite 24 - Displays Zones on Keypad when in day mode/default

    You're very welcome, Glad to be of assistance.
  11. R

    Texecom Premier Elite 24 - Displays Zones on Keypad when in day mode/default

    I can, enter the engineer code-it should display 'program zones', press 3, then yes, will take you into 'Global options'. Scroll to 'System config', press enter, type in 56, if you're on 'view open zones' press no, and it should change to no. Press menu a few times until the display asks if you...
  12. R

    Texecom Premier Elite 24 - Displays Zones on Keypad when in day mode/default

    This is probably being caused by this parameter, it can only be altered using the engineering menus.
  13. R

    Texecom connect / smartcom issue

    Just wondered, as i had a system suffer a lightening/surge, took out one of two keypads, the panel, an expander, dualcom, and two of the pir's, the smartcom survived, followed normal procedures on the cloud to 'replace' panel, but still had connection issues, Texecom advised me to check IP...
  14. R

    Texecom connect / smartcom issue

    252 by any chance?
  15. R

    Alarm Wiring, HELP!

    Link=small piece of wire 'linking' the two terminals for zone 7. Put all wires back in any zones you taken out, put a 'link' in zone 7 terminals-the problem zone, and report back.
  16. R

    Texecom adding wireless keypad or sounder

    The panel will support a maximum of 24 zones, the panel has 8 zones on-board, to use more zones you fit an 8 zone expander, expander 1 will give you zones 9-16, expander 2 will give you zones 17-24. If you want to incorporate wireless devices you can fit an expander that will allow wireless...
  17. R

    Texecom adding wireless keypad or sounder

    If you have the engineer code you can confirm how many zones you are using, if you have a wireless expander fitted etc, and a plethora of other things relating to the system, as long as you know what you're doing/looking for-you can also seriously muck stuff up if you dont!
  18. R

    Gardtec 300 Query

    Is there a contact on your exit door?, if so give it a few sharp taps, sometimes they can stick causing the system to not see the door shutting.