Search results

  1. geraldthehamster

    Support roof over door opening

    Is the 2" of the door frame part of this structure? If not, do you think I could site the two 6x4s [edit - I mean 6x2s] behind it, on the top of the pillar built each side of the opening?
  2. geraldthehamster

    Support roof over door opening

    Gable ends, yes. A purlin is also a possibility
  3. geraldthehamster

    Support roof over door opening

    That's food for thought, thanks.
  4. geraldthehamster

    Support roof over door opening

    Any way to get the height down from what you've suggested? Using 4x2s and screwing and glueing to the door frame gives a total depth of 6", but I guess that's insufficient.
  5. geraldthehamster

    Support roof over door opening

    Thanks. There's still a course or two of bricks to go on, front and rear, to give a level wall plate. "Gauge" ;-)
  6. geraldthehamster

    Support roof over door opening

    I am building the outbuilding pictured, in my garden. It's 4.8 x 3.2. It will have a 24 degree cut roof with the ridge running lengthways, with clay tiles. Can anyone suggest what size and material lintel I could put over the 2.6 door opening, to support the roof at that point? Around 4...
  7. P5260002

    P5260002

  8. geraldthehamster

    Weight on glass conservatory roof.

    Bl**dy hell, don't
  9. geraldthehamster

    Sky Lantern

    Nobody will go to that effort to steal a skylight
  10. geraldthehamster

    Potential Issue with Condensation

    That would be correct assuming the void is ventilated. I still think this is overkill for a shed. You may be heating it, but unless you're living in it where will the moisture come from? Condensation is caused by moisture held in warm air condensing out when the air is cooled, as cold air can...
  11. geraldthehamster

    Potential Issue with Condensation

    The air gap should be on the cold side of the insulation, but only makes sense if the gap is ventilated. Otherwise put the insulation hard up against the roof. But this is all to do with preventing condensation in the roof straucture, rather than the shed. Personally I think you're unlikely to...
  12. geraldthehamster

    Replace glass on wooden frames

    I would never replace good timber frames with uPVC.
  13. geraldthehamster

    Boundary Dispute

    I've lost track of whose house is which, but it looks to me that what was a gentle curve has been turned into an angle by the installation of the slabs. The triangle looks to belong to the house with the garage - it can't be part of the drive of the house with the door and window - you can't...
  14. geraldthehamster

    Party wall dispute with neighbor - what are my rights here

    Fixing the drainage is the thing you should discuss with the neighbour. As to the rest, I agree with those who have suggested you're taking the p155. You can't design a development around redesigning your neighbour's garage roof.
  15. geraldthehamster

    Clearing out Chimney Ash Pit

    looks like its already been made smaller to accommodate the electric fire.
  16. geraldthehamster

    Doorstep Bricks

    They'll be fine, they're concrete blocks
  17. geraldthehamster

    Party wall dispute with neighbor - what are my rights here

    Correct. The OP would bear the cost of any and all surveyors involved
Back
Top