  1. Echo the husky

    Mysterious sound of running water

    Does everything else in the property work with the valve closed?
  2. Echo the husky

    Boiler firing constantly for hot watere

    I assume that is some sort of electronic cylinder stat? Not seen one like that before in the many unvented water heaters I've wired up. I wonder if it is programmed to cycle that way??
  3. Echo the husky

    1 cm thick limescale in toilet

    No where near as fun as the chemistry experiments though.
  4. Echo the husky

    Crosswater Digital Elite : No Water

    I've just looked up a photo of that unit, there is quite a lot of electronics in there. When you say no water from shower head, do any of the other outlets work? Or is the shower head the only one connected?
  5. Echo the husky

    Replacing honeywell thermostat from old to new digital

    What is the model number of the thing it is attached to?
  6. Echo the husky

    Washing machine dual feed

    If you use 40C or lower wash cycles the hot water valve will never open.
  7. Echo the husky

    Honeywell motorised valve issue

    As above it is likely the valves need replacing, but before you buy new valves, cut the mains power to the entire heating system. If they spring return then, you have a wiring fault, if they stay as they are they need replacement.
  8. Echo the husky

    Identify central heating programmer

    This is a Salus EP200, it's missing the hinged cover on the right of the unit.
  9. Echo the husky

    Hive Wiring to Replace Watts BT-WR02-HC RF Receiver for Underfloor heating

    Do you really have a gravity hot water system? Most of these systems have been removed years ago due to the huge inefficiency. If you can run the radiators without the hot water being on at the same like you have a fully pumped system, not gravity.
  10. Echo the husky

    Replacing Danfoss 4700 and Actuators

    The wiring could use some improvement, single insulation shouldn't be visible outside the enclosure, each channel has 2 pairs of terminals for the actuators so there is no need to shove 2 wires into the same terminal etc...
  11. Echo the husky

    Problems with Hive - radiators not heating

    No electrician would install wiring like that, whether they knew about central heating systems or not.
  12. Echo the husky

    Boiler replaced not turning off after CH demand from nest has ceased

    That is not wired for Y plan, it looks like S plan. Y plan has a single valve, S plan has 2 separate valves. Assuming the system works properly with the old controller and all the wires in the loose connector blocks haven't changed, the nest looks like it is wired correctly. The black wire...
  13. Echo the husky

    Am I doing this right? 2 gang dim light switch wiring

    Don't forget to earth the metal plate.
  14. Echo the husky

    Pushfit

    I've seen plastic water pipes leaking from squirrels chewing through them.
  15. Echo the husky

    Am I doing this right? 2 gang dim light switch wiring

    That's quite a mess. I would recommend calling an electrician.
  16. Echo the husky

    Fluorescent batten starter

    I hate it, we chuck away loads and loads of failed LED fittings now, instead of just putting in new tubes and starters like we used to. The amount of within guarantee period replacements we do is shocking. I replaced 2 new fittings in an office before Xmas that had failed after 5 weeks! We have...
  17. Echo the husky

    Wire demister in room with dimmer switch

    The MK rollover dimmers were available years ago but not now and had a rocker switch that fed a dimmer and had the aux un dimmed terminal. Ideal for switching on the wall lights while being able to dim the centre lights. Tap Tile touch sensor switches also have a separate dimmed and non-dimmed...
  18. Echo the husky

    Mira Vigour shower, no powerful

    Did you fit the brushes correctly? Are they free to move in and out? Are any connecting wires properly connected to the motor? Is the motor buzzing/humming? Can you post a close photo? It might show possible problems.