  1. Ab12

    UFH, combi and seperate CH

    Thanks for this. It could be a way forward. Out of interest do you have any resource I can read for how that is wired up for a mid position with a Ch and HW cylinder setup. I assume from the photo you attached that for example the mid position valve would always be on open one way I.e. for c...
  2. Ab12

    UFH, combi and seperate CH

    Nothing at all sadly. Which bit is a mess out of curiosity, wondering what aspect?
  3. Ab12

    UFH, combi and seperate CH

    I'm not sure, I'd assume so yes... Could I use a timer to do this? Again have not a clue.. All I know is it's how it was left and I've run out of money to get it done.. so really need to get this heating going
  4. Ab12

    UFH, combi and seperate CH

    Yes, I'd want to be able to have the upstairs heated without the downstairs (i.e. rads on without ufh)
  5. Ab12

    Wiring and plumbing for UFH with a Vaillant ecotec combi boiler

    Be interested in you sharing that...
  6. Ab12

    UFH, combi and seperate CH

    Photos attached of what I've been left with. The coloured boxes are the valves that will run together in each zone/room
  7. Ab12

    UFH, combi and seperate CH

    But the salus centre I have is wired. The rads one would be wireless. In that case id need two salus boiler controllers a wireless one for the rad stat and a wired one for the Ufh control centre right?
  8. Ab12

    UFH, combi and seperate CH

    I have different zones but they are controlled by the wiring centre which the Ufh stats run to right?
  9. Ab12

    UFH, combi and seperate CH

    No idea. I heard it needs to be some form of S plan. Not sure if it's what I need..
  10. Ab12

    Euro46 PIR MEBQ wiring help

    Thanks, seems I did! Managed to work out which ones re which. Just a question, does it matter that yellow and blue are not the same placed as yellow and blue on the control panel. I.e. blue is on T in control panel, but yellow is on T in the PIR?
  11. Ab12

    UFH, combi and seperate CH

    After a bit of help with the wiring for my boiler, CH and UFH. All plumbed in but the plumber has now done a runner and I'm out of money. Figured I can do this myself (just wired in my alarm system), plumbed and done electrics before. I'm just stumped with how to setup the S wiring. Here's...
  12. Ab12

    Euro46 PIR MEBQ wiring help

    How can you tell they are 4.7k. I have another strip but they're the same colour...?
  13. Ab12

    Euro46 PIR MEBQ wiring help

    If I do what's in your pic then I assume that's EOL? If 4 wires + power then that's NC right? Which resistors are the right ones for whats needed? Either of the two in this photo? Thanks
  14. Ab12

    Euro46 PIR MEBQ wiring help

    Hi guys, Trying to get the MEBQ PIRs wired into the euro 46 v10 pyronix main unit, but a little confused with the wiring as the manual shows wiring of a PIR with integrated resistors Could someone help me work out if I'm doing it right as EOL. Also these are the resistors (in photo) that came...
  15. Ab12

    Pyronix diallers help

    Yep, euro46 v10 Ideally I'd like to be able to set/unset from my phone but also have other people be alerted to any alarm activations/if it goes off (dialled or sms'd not via push on an app which they wouldn't have) Can the GPRS+ SIM work alongside the standard landline dialler?
  16. Ab12

    Pyronix diallers help

    I have a pyronix euro V10 system. It currently has a standard v2tel dialler. I would like to add some form of digital access (for the app). I assume I have a choice of the LAN or a GSM/GPRS version. As I understand it the LAN version will NOT dial out or alert in any way other than push...
  17. Ab12

    Cavity insulation 100mm which type

    So 90mm 10mm gap is considered full fill then if I have a 100mm space right?
  18. Ab12

    Cavity insulation 100mm which type

    I don't need any internal wall celotex with this approach though What about 100mm celotex, I has a thermal conductivity value of 0.022 and the unilin 0.021. can't be that much different?
  19. Ab12

    Cavity insulation 100mm which type

    Would you mind letting me know how you calculated that! Just incase I get a different type of full fill 100mm cavity ?
  20. Ab12

    Cavity insulation 100mm which type

    Thanks! Would these be okay then - full fill 100mm as you mentioned above. Cavity is fixed at 100mm https://www.insulationshop.co/100mm-unilin-thin-r-ctpir-cavitytherm-full-fill-insulation-pack-of-4.html?limit=50