  1. M

    Damp proof course ??

    This is grabbed off another page but is basically how its built at the moment my feeling is penetrating damp can come across from the external wall as there is no dpc method been using on the vertical run
  2. M

    Damp proof course ??

    Pictures not the best but you can see how the white paper wall would go over
  3. M

    Damp proof course ??

    Yeah i have kept one lenght of dpc all the way there is no joins in it One issue i have is one of the internal brick walls goes right over the cavity and joins the external wall i dont know if it has been build like this for strengh or what ive the bottom section away but dont want to carry on...
  4. M

    Damp proof course ??

    Also to note im only doing this on the internal skin not both skins at oncs
  5. M

    Damp proof course ??

    Thanks for the advice yeah the cavity was full of crap... the bricks in this house dont have sand and cement between them its like coal dust mix what they was trying meaning the bricks come out very easy you dont need to hammer so much to get them out as you would if they was sabd and cement. Im...
  6. M

    Damp proof course ??

    The outside wall are brick cavity walls The inside dividing walls are single brick down to the ground and they have damp issues aswell so was going to do the same with them
  7. M

    Damp proof course ??

    Hi guys so trying to fix a issue with rising damp on the internal skin and inter solid bricks walls my plan is to go along taking the bricks out bit by bit in stages and install a dpc like the images shows , just to get advice im i doing this correct and will method work ? i understand you can...
  8. M

    60a supply upgrade to 100a ?

    Yeah thats a point i mean it could bypass the one on the domestic side and still blow the dno one
  9. M

    60a supply upgrade to 100a ?

    Haha yeah maybe a future plan but no i just though the mondern way if you was doing upgrades was to upgrade to a 100amp im learning and gaining a understanding like what does a average house run at amp wise any way near 60 80 or 100 im guessing not
  10. M

    60a supply upgrade to 100a ?

    yeah abit silly really i suppose one plus would be that if you did get to the 60amp limit and blow it your blowing your own fuse that you can replace if you blew the main service fuse whats the time scale of being with no power for the dno to come replace the fuse ? ive mentioned to BG that i...
  11. M

    60a supply upgrade to 100a ?

    Ok thanks i just though going to 100a was the modern way to go , on the current setup i have the dno supply meter and consumer all in the same area i have BG coming out to fit a isolator switch as the current setup dont have one If i keelp the current 60a supply and the meter and supply stays...
  12. M

    Rotten ends on floor joist

    Cavity has been full of **** so all been wet in there likey what has made them rot ive been cleaning it out
  13. M

    Rotten ends on floor joist

    Hi mate most the ends are shot its quite solid floor under the joist so would you suggest just putting legs on each joist ?
  14. M

    Rotten ends on floor joist

    hi guys got some floor joists that have rotten ends where they go through into the brickwork pockets i wanting to cut the rotten ends off and brick up the pockets what would be the best method to then re stable ? maybe metal brackets screwed into the brick or brick pillars ? cheers
  15. M

    60a supply upgrade to 100a ?

    My responce ye ye Good morning Mark, I can appreciate your concerns with the quote issued. We are regulated by OFGEM and we do not make a profit for our works, the prices are set to cover the cost of the works in full, such as admin fees, staff costs and materials needed to complete the...
  16. M

    60a supply upgrade to 100a ?

    Again "GREED" its all about more more more and not a fair price , for anything these days its not what its worth its what can folk get away with getting
  17. M

    60a supply upgrade to 100a ?

    Way of the world now aint it.. which im all for safety but yeah i still think its a pants down quote... so yeah i laft to work around where its at already lol
  18. M

    60a supply upgrade to 100a ?

    1 hour for this guy..... litrally i repeat a joke
  19. M

    60a supply upgrade to 100a ?

    But in answer its half a days work at the most for 1 man so i would of expected to pay likey no more then about 300 quid with it being a big company 1k is deffo a joke when everything is fitted and dug for them Like dont big it up they come onsite Pull the a new bit of cable into my box that...
  20. M

    60a supply upgrade to 100a ?

    Probley driven by alot of greed... as always just like how its gone with alot of local trades.. 300 quid a day jobbers and such then you get shot down while they reel off all there overheads half the tools they dont actually need like the 40 odd k ford msrt full kit van what ever did the sparks...