  1. C

    Drain holes in DPM

    No,the floor should be sealed and a drain if a wet room
  2. C

    Faulty boiler thermostat

    Also check the brass base valve turns easily
  3. C

    Faulty boiler thermostat

    When you have the stat removed of its back plate ( probably 240 v) is it still firing the boiler ,if no probably the stat if yes probably a zone valve issue assuming it’s only just started happening
  4. C

    Midland Brass isolating valves

    They have none return built in
  5. C

    Double glazing old wooden frame

    Have you considered secondary glazing
  6. C

    How to install Hive on Ariston Ecombi One (Ed)

    Has your boiler a built in clock ? If so it need leaving to permanent on .
  7. C

    Is there/should there be a tundish here?

    The black plastic bit 1/3 of the way down on the left.
  8. C

    Combi Boiler Overheating (Potterton Titanium 40 )

    Filter in return clear ?
  9. C

    boiler siting in bathroom

    If you have or download the manual for your boiler it will give advice on boilers in shower room
  10. C

    Correct way to plumb in rads.

    they should be connected from the heating flow and into the return if you have a Two pipe system ,if it’s a one pipe you are never going to get good performance from tall rads.
  11. C

    Drop in Temperature on Bar Shower

    Check mixer taps / shower valves one may be passing cold into the hot
  12. C

    Water pressure suddenly low in house after boiler repair

    You say “ halfway through he fitted a valve “ is that still in place
  13. C

    Water pressure suddenly low in house after boiler repair

    Have you a internal stop tap they may of tried to close
  14. C

    Dual button flush valve

    They normally push on separate parts of the valve , have you took lid off ,may need rod adjusted
  15. C

    Help with toilet cold feed pipework layout

    Yes you can put it straight through ,no check valve needed
  16. C

    Drayton trv4

    Is the thermostat in a position that gets air flow ? Or is it blocked off by curtains / furniture
  17. C

    Between joist underfloor heating output requirements

    Just because you have a 2 kw rad now doesn’t mean it was ever calculated , use a online calculator and input your room sizes first
  18. C

    Reducers on trv

    No,soldered ones are better if copper pipe
  19. C

    Central heating loud clanking when heating up

    Sounds like “ kettling” it’s when the heat exchanger starts to scale up ,x200 may help eventually
  20. C

    Vibration in system only when the hot water is heating

    Sounds like it’s running dry,check your heating cold feed is clear