  1. D

    Steel column pad base questions

    2m 4m or 8m its all the same really just the logistics of placing the beams a bit more involved , as long as its structurally sound and all the i's are dotted and tee's crossed its going to be a great project
  2. D

    Steel column pad base questions

    Stevie out of interest 1.2 x 1.2 = 1.44m2 so 2nr = 2.9m2 which is less than 8 x 0.6. Similarly 0.9 x 1.2 x 2 = 2.2 which is less than 8 x 0.45 Since both calcs give a discrepancy factor of 1.6 am I missing something?
  3. D

    New stopcock turns but does not shut off water

    Isolate with WC boundary box isolation valve, whip stopcock valve head/handle off and inspect
  4. D

    New stopcock turns but does not shut off water

    Just put a large screw driver against the valve with the handle against your ear and you will hear any passing flow
  5. D

    Central heating

    Do you have TRVs and lockshields valves on your radiators? Re pump speed that all depends on how effective the pump in distributing the flows to all radiators and is particular to the system its serving, generally lower the better for a bit of energy saving but start on 1 and progress upwards...
  6. D

    Structural engineer not attended property

    CAD technician (draughtsman)????
  7. D

    Bodge fix to slow leaking radiator connection -better rad on or off and plumber mait? denso tape?

    No need to completely drain the system, just depressurise it and shut valves at both ends of radiator. Then the bottom nut can be released and if possible (since you cannot drop the feed pipe down) lift the end the radiator up so the olive on the pipe is accessible and then wrap 5 turns of PTFE...
  8. D

    Bodge fix to slow leaking radiator connection -better rad on or off and plumber mait? denso tape?

    Definition of not to high? Since the OP re pressurised I guess it's at least 1 bar and 1.5 bar when up to heat?
  9. D

    Bodge fix to slow leaking radiator connection -better rad on or off and plumber mait? denso tape?

    If you haven't any plumbing skills it hard to give you any advice as Herts says keep topping up till Monday and accept/ deal with the spillage. Friday the kids will have gone and you can leave it alone?
  10. D

    Detached double garage - wall thickness

    No disagreement there, easy enough to work out wind pressure/forces on external walls and resulting overturn in moments and then confirm any buttressing walls/piers provide adequate resistance
  11. D

    How to reset garage cable back into groove wheel?

    Probably Probably more than a minute but I get your drift
  12. D

    Two sets of roof joists - new hatch opening

    Well if your trimmers are adequate to take the loads to the outer joists and the joists are of sufficient strength to take the extra load then fine, anything is allowed if it's structurally verifiable
  13. D

    How to reset garage cable back into groove wheel?

    Probably/possibly/definitely depending on what your plan of action is to remedy your problem. My advised method way back when was basically taking the tension off the wire by clamping onto the drive shaft with something and turning it backwards 1/2 a turn against the force of the spring, adjust...
  14. D

    Two sets of roof joists - new hatch opening

    So when you have cut all the joists and fitted your hatch frame in whats to stop the cut joists in the 3m span direction wanting to drop down?
  15. D

    How to reset garage cable back into groove wheel?

    Sounds to me that your videos are about completely retightening a spring on the shaft by rotating the loosened spring retaining block around the shaft then tightening some grub screws hold it in position, nothing to do with my method but more than one way to skin a cat, good luck
  16. D

    Best way to strengthen this joist notch?

    Something like this perhaps on the other side of the joist
  17. D

    Detached double garage - wall thickness

    "And here are the wind loading/stability calcs that go with them to prove their structural integrity cos I cannot find any deemed to satisfy paras in Doc A "?
  18. D

    Leaking radiator valve - downstairs living room

    Unless its compressed the pipe at the same time but thats OK because you can quickly cut and solder a new piece of pipe in place ;)
  19. D

    Detached double garage - wall thickness

    Unfortunately there is nothing in Doc A that gives deemed to satisfy guidance for single skin and pier construction and I doubt whether BC will accept "this is the pier spacing we always do" with out structural verification ( unless maybe with an old school BC officer or the garage is being...