  1. Madrab

    Poor hot water system.

    If the mains is 1.8bar with one outlet open but the flow rate is 4L/Min then there must be a restriction in the supply somewhere. If the dynamic pressure is 1.8bar then the supply should be delivering much more than 4L/Min, unless the supply is on an excessively long run of 15mm pipe. If the...
  2. Madrab

    Wodar 4 in 1 tap - pressure problem regarding mains water

    Unless your dynamic mains pressure is really good then their flow can suffer with the small waterways they use inside, what is basically, a standard sized tap body.
  3. Madrab

    Extractor fan installation

    Whilst an extractor may help - the best thing you can do, once the shower is finished, is open the door a bit and keep the window open until the room clears and cools down, natural ventilation is the best approach. Have the window open whilst showering to allow the steam a path to escape. Also...
  4. Madrab

    42 vs 40mm waste pipe

    ABS solvent weld plastic has an OD of 43mm - usually compatible with PVC as both can be glued though PVC does come in imperial and metric sizes - PP push fit plastic has an OD of 40mm. ABS and PP - for some reason - are both called 40mm or 11/2" PVC waste pipe sizes are rarely used in domestic...
  5. Madrab

    Radiator replacement - should we go for higher BTU than needed?

    More than enough - the radiator works by it heating the air it draws in from below and circulating that out the top and out into the room, it won't lose a lot of it's efficiency being close to the sofa No but I bet it got there quickly .... used to have a TVR Chimaera ;)
  6. Madrab

    Radiator replacement - should we go for higher BTU than needed?

    If you can only fit one rad then I'd use a conventional, albeit contemporary design, if you want it to look good. A Type22(K2) radiator behind the couch is proven to work well, as long as there is a reasonable air supply allowed to get to the bottom of the rad and a little space left between the...
  7. Madrab

    Hanging a rad on a plasterboard and osb wall

    If that's 9mm OSB onto proper batons then it should be ok. Try and pick up the batons for at least the top brackets and use nice large fixings, or if it's easily opened then run an extra baton in for the top brackets
  8. Madrab

    Radiator replacement - should we go for higher BTU than needed?

    Honestly - I've had clients ask me to pull designer, tubular, vertical rads out out more times than I care to remember because they just fail to heat a decent sized room properly. I removed 3 - 550mm x1800mm doubles from my own living room (26m2) because they were woefully inadequate at heating...
  9. Madrab

    Radiator replacement - should we go for higher BTU than needed?

    Heat loss calcs are designed to provide the amount of heat that a given room can lose in an hour in Kw, that is then matched to the output of the radiators at a given delta that can then replace that heat loss, that is then designed to ensure that the space is comfortable to be in. Unfortunately...
  10. Madrab

    Radiator replacement - should we go for higher BTU than needed?

    When you say horizontal, how do you mean? Just a normal convecting radiator or a designer type? You do get flat panel, contemporary looking rads that are convectors BTW.
  11. Madrab

    Underfloor pipe installation

    What is the void being filled with, on top of the KS, to create the thermal mass? Is it to be a biscuit mix? I'd also be looking to insulate the loops under the joists. I guess if to be picky then the loops could have gone through the joists and the insulation extended.
  12. Madrab

    Radiator replacement - should we go for higher BTU than needed?

    The trouble with these new designer tubular radiators is the way they heat. Classic type white radiators primarily use convection to heat the air that is drawn up through the radiator/fins and then out into the room, that cycle continues and heats the room quickly and efficiently. Their output...
  13. Madrab

    Grohe Self Closing Valve - Faulty?

    Looks like the sub standard brass casting and finishing that lots of stuff ends up like these days. A lot of it comes from Asia and is produced en masse. Will it alter the performance, if it's mains pressure then unlikely to notice much difference, lots of taps, mixers, valves etc all have these...
  14. Madrab

    Radiator replacement - should we go for higher BTU than needed?

    If you are looking at designer tubular type radiators then be aware of how they work, compared to normal convection type radiators. Albeit their output may be similar, the way they heat the space (air) in the room isn't the same, they are a lot less efficient at space heating than traditional...
  15. Madrab

    Help with water hammer

    Water hammer is primarily down to badly located/run/loose pipework that knocks against itself or something else. When a hydraulic shock is created by a fitting/valve/outlet opening or closing too quickly - usually in higher mains pressure systems - that shockwave then travels along the pipework...
  16. Madrab

    Copper hot water cylinder fitting at top leaking

    Oh my - oldy but goldy - anything possible - but it could be a struggle to get the large cap off that cylinder. It will either go ok or it will burst the top of the cylinder. That will need a pair of stilsons and possibly some heat but again, that could compromise the cylinder.
  17. Madrab

    Power Flush advice

    Yes - normally I wouldn't suggest using the boiler isolation valves, as some don't like being used if they are old and then leak afterwards but you want to force the water through the rads and any crud flushed out to be ejected out of the drain offs, you don't want any of that running through...
  18. Madrab

    Power Flush advice

    Ah - no , not the boiler drain point. I'm taking about a full system drain(s), external drain valve(s) run off of the central heating, usually set below floor level on an outside wall, where the whole system can be drained down. Some systems have radiator valves with drain points...
  19. Madrab

    Underfloor heating problem.

    Start with the parts that don't cost anything. I presume you mean 1.5bar, not PSI? No, raising it to 3.5 bar wouldn't make any difference, 1.5bar should move any airlock. If there's no flow then either the loops/manifolds are restricted or the pump isn't circulating. Do the manifolds have...