Search results

  1. Bigsosij

    Xx

    All of them
  2. Bigsosij

    Xx

    Make sure input area is set to 'any' for all zones, level set on, and b exit to timed
  3. Bigsosij

    Upgrading from Castle care Euro one+ to Pyronix Euro 76 - wiring question

    Take the id biscuits out and fit EOL resistors 2k2/4k7 and obviously wire each detecetor to its own input on the e76 panel
  4. Bigsosij

    Upgrading from Castle care Euro one+ to Pyronix Euro 76 - wiring question

    Check the wiring u may be lucky and each detector may be wired back individually to the panel. If not easiest option guna be to use what wiring you can and replace rest with wireless
  5. Bigsosij

    Help to remove A1 AJ600N security alarm

    I would say that that is the control panel with an onboard keypad
  6. Bigsosij

    Pyronix comm fault

    Or reboot the router/booster
  7. Bigsosij

    Pyronix Castle Euro46 v10 - Clean start, lan card, cloud link

    0v to C, NO to eng hold off, Change outputs > endstation outputs > pgm op > engineer access (think its number 59)
  8. Bigsosij

    Pyronix Castle Euro46 v10 - Clean start, lan card, cloud link

    Just twist the blue and yellow at the kitchen pir and wire the hall with the blue and yellow i reckon that will work. Wrt the bell does it have the tamper switch with the circle base that goes at top left or is it the old style to the bottom left of the pcb ?
  9. Bigsosij

    Pyronix Castle Euro46 v10 - Clean start, lan card, cloud link

    I think i worded that wrong lol, with them joined together in the kitchen do u get continuity on the cable from the panel to the hall? U can actually wire each detector with 3 cores if u link 0v and com in the detector, then wire the other core to eol terminal on the panel
  10. Bigsosij

    Pyronix Castle Euro46 v10 - Clean start, lan card, cloud link

    Have u tried joining the blue to the yellow on the kitchen wire, then check for continuity at the hall.... had a similar situation this afternoon with a hidden joint
  11. Bigsosij

    Pyronix Castle Euro46 v10 - Clean start, lan card, cloud link

    Looks like theres a stripped blue and yellow pair in your pic which isnt twisted up with the rest of the spares....
  12. Bigsosij

    Pyronix Castle Euro46 v10 - Clean start, lan card, cloud link

    Press c to clear before entering new manager code then press yes and exit eng
  13. Bigsosij

    Pyronix Castle Euro46 v10 - Clean start, lan card, cloud link

    1111 is eng code, you can reset the master code in the eng menu
  14. Bigsosij

    Pyronix Castle Euro46 v10 - Clean start, lan card, cloud link

    Default manager code is all the 2s u will need to go into manager menu to change this or to add a user code
  15. Bigsosij

    Accenta G4 PCB replacement

    Take the wires from the tamper and 0v terminals and cocnnect to the negative terminal of the battery as they may be mixed up at the bell end. Attach 12v supply to positive battery terminal. Thtis should soslve your issue.
  16. Bigsosij

    Eaton control panel ploblem

    Link out the bell tamaper return in the panel and see if it clears
Back