    Accidental nick to socket cable

    Can I move the socket down 8cm so it's 28cm from ground (is this ok and in accordance with UK regs)? If I can then I don't need to create another joint
  2. T

    Accidental nick to socket cable

    I don't know if the earth wire was nicked aswell Happy to move the socket down provided the socket can be 28cm from ground? From what I've read all electrical joints need to be accessible and this is best practice
  3. T

    Accidental nick to socket cable

    I have read that electricians don't like maintenance free joints as they can't see them so my plan of using 3 x 32A inline spring connectors inside a backbox covered by a 1 gang plate (which is accessible) seems to tick the boxes. This plan allows the joint to be accessed whilst using Wago...
  4. T

    Accidental nick to socket cable

    I would use an in line spring clamp connector (https://www.toolstation.com/wago-221-2-way-inline-lever-connectors/pAC293) with no heatshrink tubing (as it's not needed I just remove 1cm off sheath off line/earth/neutral. The 3 connectors would be inside a 1 gang accessible backbox covered by a 1...
  5. T

    Accidental nick to socket cable

    Is about 1cm bare copper on each end of the cable enough to fit into these wago in line connectors?
  6. T

    Accidental nick to socket cable

    ignore
  7. T

    Accidental nick to socket cable

    My mistake the 45cm socket height is recent guidance not a requirement
  8. T

    Accidental nick to socket cable

    I have no experience with heat shrink tubing and the 'WAGO 221 2-Way Inline Lever Connectors 32A 0.2-4mm²' (https://www.toolstation.com/wago-221-2-way-inline-lever-connectors/pAC293) is lever compressed (no soldering/special tools/heat shrink) needed so I (as a DIY'er) can do this myself...
  9. T

    Accidental nick to socket cable

    No I'd rather just cut the nicked cable 8cm (where the nick is) then join live/neutral/earth together with the 2-way line wago connectors (wago connectors would be inside an accessible 1 gang backbox with front plate). Not going to replace the short piece to socket. Sounds ok?
  10. T

    Accidental nick to socket cable

    There is not enough flex in the cable for 180 degree turns. So I would use this wago instead x 3 (one live one neutral one earth): WAGO 221 2-Way Inline Lever Connectors 32A 0.2-4mm²: https://www.toolstation.com/wago-221-2-way-inline-lever-connectors/pAC293 is this ok?
  11. T

    Accidental nick to socket cable

    So, out of the options below: 1. Connector Strips 30A, https://www.toolstation.com/connector-strips/pAE651 2. In Line Spring Lever Connectors 3 Pole 32A, https://www.toolstation.com/in-line-spring-lever-connectors/p78346 which one would you pick and why?
  12. T

    Accidental nick to socket cable

    I've read that electricians don't like hidden maintenance free joints behind plaster and that one should use visible plates for access. Also, as the ring main is 32A I would use a Spring Lever Connectors 3 Terminal 32A (https://www.toolstation.com/in-line-spring-lever-connectors/p78346) which...
  13. T

    Accidental nick to socket cable

    Just tried no afraid not
  14. T

    Accidental nick to socket cable

    I have accidentally nicked a 2.5mm2 twin/earth cable going from the 2 gang socket downward under the floorboards to the consumer unit. The consumer unit did not trip and I think the neutral wire (located about 8cm below the socket) was nicked and I did not get electrocuted and the socket works...
  15. T

    Oil tank additives/cleaner e.g. sludge buster

    Worcester Bosch on callout did a dip check in the oil tank and said there was no oil. Fault was one of the oil burners that failed and caused soot to build up. Back up and working. I don't have an oil water separator installed but I did buy a tank sock. Although I'm not OFTEC certified could I...
  16. T

    Oil tank additives/cleaner e.g. sludge buster

    After my oil boiler began spitting out black smoke/soot which was 2 days after a recent kerosene (heating oil) top up I am getting the manufacturer (Worcester Bosch) on callout to clean the boiler. The boiler itself repeatedly gave error 9F 855 (probably airlock) and repeatedly cut out. The...
  17. T

    Insulate garage door and fill gaps at side

    I only used a mixture of 150mm and 100mm block insulation with expanding foam and grab adhesive on the back of the garage door. All the door is 150mm overall. I did not use screws. I fitted upvc 1.2-2mm white plastic trims to the edges carefully making sure that the trims did not interfere with...
  18. T

    Insulate garage door and fill gaps at side

    Yes the bar rotates but the garage door rotates when the bar rotates. I can only adjust the spring with the garage door closed/shut or slightly open. Do people normally adjust the garage door spring with the garage door shut or slightly open? In the video I have seen where the garage door...
  19. T

    Insulate garage door and fill gaps at side

    The hole in the bar is from below so I assume you mean the crook pin needs to hook over the tube from below? To hook the long end of the crook pin over the tube I need to hammer the the crook pin, as in position in JPEG 'crook pin position' upwards. Can't see another way of doing it. Am I right?
  20. T

    Insulate garage door and fill gaps at side

    I've attached two pics of the crook pin orientation. I think the 2nd JPEG photo showing the crook pin with the long bit over the white bar is the correct position. I want to make sure this is the correct position. Which position looks right?