Search results

  1. secureiam

    Programming Outputs : output does not activate

    Probably as above, the mains power off is fault but wouldn’t report on coms, however mains power off is a specific condition. I suspect it’s down to the reporting codes and how they work, these can be changed but wouldn’t recommend it
  2. secureiam

    Texecom premier elite - zone default to omit

    it maybe possible, would have to have a play. You can force omit attribute in the zone, then force the zone to remain open before and during the full set only and not the part part set. The problem is the zone has to be active at the time of setting for the force omit to come into play and...
  3. secureiam

    Replace Ring Doorbell with Hikvision

    There’s been a few issues with how you add the doorbell to record the video 247. You would think it be possible. Not 100% sure why it’s not possible, I would guess you might be able to cheat the system for the NVR to provide the power and plug into a non POE switch. For the network...
  4. secureiam

    Programming Outputs : output does not activate

    Which output are you using ? What device is it triggering? Was the mains off registered in the event log?
  5. secureiam

    Texecom Premier Keypad cause ticks sounds

    believe it’s intended behaviour and may even be officially documented.however no sound should be no sound. Something is telling me that it has been brought up before and completely slipped my mind. Then again it might have been certain versions of keypads and panels or after a certain version...
  6. secureiam

    Pyronix Delta Bell - Hard wired / battery?

    Your eye sight is better than mine
  7. secureiam

    Pyronix Delta Bell - Hard wired / battery?

    Can you post a picture of what it is you though was the battery, you give a very specific reference. It does use a battery but its unlikely to need replacing for a very very long time
  8. secureiam

    Texecom Premier Keypad cause ticks sounds

    well its clear as suspected it isn't power supplied being the issue. without hearing the tick its hard to say. You can make the keypads tick by changing the tones of the keys when pressed. If you press Yes and Menu together then press yes until you get to Keypress sounds, does it say click...
  9. secureiam

    forum access

    Hmm struggling at the minute with access to this forum, behind a vpn at the minute which appears to work, not sure whats going on. can access everything else just not this from my ip address. Can admin advise via registered email please. greeted with a single line error message to try later.
  10. secureiam

    Pyronix Delta Bell - Hard wired / battery?

    Hmm, the cylindrical battery you refer to is for the Mk1 wireless bell not a hard wired bell Mk2 uses2 square Mk3 uses 4 x cr123A batteries. The hard wired bells use Nickel metal hydride battery not lithium Pretty much wireless uses a lithium battery set, hardwired Nickel batteries main...
  11. secureiam

    Texecom Smartcom - Cloud Stopped working

    well if you had been free like so many other you would have probably let me know and I could of provided the number then, or like so many others they just look me up.. if your free later today let me know
  12. secureiam

    Texecom Premier Keypad cause ticks sounds

    cant see power being a being issue with one pir and one smoke, the network has 1 Amp to play with, 300mA for the keypads and the expander and at a push around 100mA for the two devices, but to be certain you can look up consumption in alarm
  13. secureiam

    Texecom Smartcom - Cloud Stopped working

    gove us a call after 10pm but before 10:30pm can go through a few things with you then, just writing some quotes up at the minute
  14. secureiam

    Texecom Premier Keypad cause ticks sounds

    POWER or INTERFERENCE as adding the 8XP is when things started I would measure voltage getting to the keypad and the expander. I would disconnect the expander power and T and R and see if that resolves the problem and measure the voltage at the two keypad this will give an idea if its power...
  15. secureiam

    Texecom Premier Keypad cause ticks sounds

    Check power, check interference. Without seeing hearing it can’t comment much more. i am aware of the keypads may do a clicking sound and usually applies to power or interference and isn’t permanent, but it does suggest something isn’t right.
  16. secureiam

    Pyronix enforcer lost engineer code - how hard to reprogram?

    There is a video with it on you tube but labelled as default codes.
  17. secureiam

    Texecom Smartcom - Cloud Stopped working

    the app would tell you if you can log into it. download the smartcom manual its available online will give you the process (google AI searches give the procedures these days). once you have the ip address changed you will need to generate an app code then create a Texecom cloud account and...
  18. secureiam

    Pyronix enforcer lost engineer code - how hard to reprogram?

    look at code default videos on you tube
  19. secureiam

    Texecom Elite 48 remote control by WLTE relay

    No worries, its hard to follow as to fault and solution but it is there. The wiring was incorrect for the wiring type chosen, ie wired double pole but using normally closed.
Back