Search results

  1. secureiam

    Texacom Veritas walk test

    to the top is correct, there is a slot on the black slider at default it set to 2k2 4k7
  2. secureiam

    Texacom Veritas walk test

    If you have an r8 plus you can change to use resistors but all devices wired in would need resistors of the same values. Then you can use a to d.
  3. secureiam

    Texacom Veritas walk test

    Not a and d
  4. secureiam

    Texacom Veritas walk test

    Change the slider to zero, wire to a and b that’s inside pir, check it’s unlocked and slide off
  5. secureiam

    Texecom premier all part arm options showing in app

    In the old app, the option wasn't there, however in the new app its an empty box, it would make more sense if the designer had made it so no text removes a box and centres what's left. That shouldn't be too hard for a developer, but it testing it on all the various different smart devices blah...
  6. secureiam

    Hikvision doorbell camera

    Not heard anything so no idea. Either they haven’t got round to it or it’s fixed.
  7. secureiam

    Texecom premier all part arm options showing in app

    Tested and yes it removes text but doesn’t disable the arming. Maybe raise it on their forum or with their tech support.
  8. secureiam

    Texecom premier all part arm options showing in app

    You need might need to talk to Texecom. The fact the text is no longer there, suggestions the app has updated. However it is possible that this version of the app keeps the place holders. I will test shortly to confirm
  9. secureiam

    Texecom Smartcom Install Issue

    You could talk the user over how to generate an app code, you don't need to be onsite.
  10. secureiam

    Texecom Smartcom Install Issue

    Register on the Texecom cloud
  11. secureiam

    Mobile Texecom Keypad App No Notifications

    You will need to contact Texecom then, very little else Without having a play and not convinced I will get anywhere.
  12. secureiam

    Gate alarm

    or keypad
  13. secureiam

    TEXECOM CONNECT says "offline" and can't get past login screen

    you need a login for the cloud and then you can register the panel in the cloud. you need engineers code and a app code less than 60 minutes old
  14. secureiam

    TEXECOM CONNECT says "offline" and can't get past login screen

    Have you generated an app code ? has the panel been registered on the cloud?
  15. secureiam

    Gate alarm

    Possible nothing broken? Panel would not show any faults for chime being turned off. It would possible show faults if the wiring was wrong, although panel speakers don’t usually show up as a fault if not wired. Normal speaker sounds would still work.
  16. secureiam

    Gate alarm

    Does the panel have a chime button, at the moment it sounds like the relay is working, the bing bong is not, which is a door chime like thing. That could have been disabled when the panel lost power in the power cut.
  17. secureiam

    Gate alarm

    So just bell that’s dead then? And possibly panels bell fuse blown?
  18. secureiam

    Gate alarm

    With you think these needs a deeper look, doesn’t add up. The relay works via the panel, panel not triggering bell after power cut. What was cause of power cut?
  19. secureiam

    Gate alarm

    What bell what panel?
Back
Top