Search results

  1. N

    Advice on painting new stair parts

    Cheers opps for your excellent advice
  2. N

    Advice on painting new stair parts

    Will using the oil darken the doors? Because I want to keep them as light as possible
  3. N

    Advice on painting new stair parts

    Also need some advice on what product to use on new interior engineered oak doors. I was thinking maybe a clear varnish? Any advice appreciated
  4. N

    Advice on painting new stair parts

    Cheers. Thanks.
  5. N

    Advice on painting new stair parts

    Just a quick question opps. My friend has given me some Dulux water based primer/undercoat. Was thinking of using that as my first coat. Would that be ok?
  6. N

    Advice on painting new stair parts

    Ok thanks very much for all your advice.
  7. N

    Advice on painting new stair parts

    So if I go for eggshell, just swap the gloss out for eggshell in your previous instructions?
  8. N

    Advice on painting new stair parts

    Never really considered eggshell as I’ve just always glossed wood. What are the pros and cons? Does it give as good a finish as gloss?
  9. N

    Advice on painting new stair parts

    Thanks oops. A very informative reply. There isn’t much natural light in the hallway but would rather use oil based gloss. When you say oil based gloss tends to yellow without natural light, over what period of time does this happen? Thanks
  10. N

    Advice on painting new stair parts

    I have installed new stair parts inc newels, spindles, hand rails and base rails. These are all made from pine. I would like some advice please on how to achieve the best painted finish with white gloss. Which brands ? Etc Many thanks
  11. N

    Newel post and handrail question

    Just wondering if anyone had done it like this or whether they made the newel post shorter so it joins the handrail at a different point
  12. N

    Newel post and handrail question

    Yeah the bottom newel and half landing newel are 1500mm. The issue is that the handrail joins the bottom newel at a different point to that on the half landing newel. Wondering whether that will look ok before I do it?
  13. N

    Newel post and handrail question

    I’m currently replacing all my stair parts. I’ve replaced the newel post at the bottom of the stairs and I’m currently in the process of replacing the newel post on the half landing. I’ve measured 900mm from the pitch line to get the height of my hand rail from the bottom newel which will sit at...
  14. N

    Worcester 24cdi no hot water

    Problem solved! I noticed,when looking at the diverter valve diaphragm pin from underneath that the black plastic disc was missing from it therefore it couldn’t operate the switch. After a quick look around I found it wedged between the floor boards under the boiler. Reattached it and now hot...
  15. N

    Worcester 24cdi no hot water

    Maybe just another thing to consider regarding the micro switch. When i removed the two wires connected to it I noticed they were both the same colour (pink) so I assume that it doesn’t matter which way round they go when reattached?
  16. N

    Worcester 24cdi no hot water

    Thanks for that video old&cold. Is it important that the switch stays together because when I took mine off the casing came apart which looked natural to me and not that it had split. So when I put the switch back on I just put the plastic casing of the switch back together
  17. N

    Worcester 24cdi no hot water

    Thanks for your reply. When inserting the screwdriver am I looking for some kind of switch to operate. Would this be better observed with the micro switch removed? Luckily we have an electric shower. Although the water was luke warm last night when we had the heating on for a bit
  18. N

    Worcester 24cdi no hot water

    Not had a chance to check it as I’m in work today. So let me get this right. When there is demand for hot water, the diaphragm moves the pin which activates the switch which kicks the boiler in? And is it possible for me to view the pin without having to remove the heat exchanger? Also, what...
  19. N

    Worcester 24cdi no hot water

    Is the contact area the small black disc? Also if I take the micro switch off and then switch the boiler control to DHW would I be able to see the switch activate? Also does the switch operate the diaphragm or does the diaphragm operate the switch?
Back
Top