    Rising main, should I convert 15mm to 22mm?

    All depends on what service pressure/available flow/length of pipework to be replaced/ what flow is acceptable. My supply is more than adequate with house approx 15m from boundary box and fed by 1/2 inch copper pipe. Normal header tank storage no combi boiler.
  2. D

    Rising main, should I convert 15mm to 22mm?

    Standard minimum acceptable value for flow at edge of property stop valve is 9l/ min, depending on where your tap is on the system your supply seems to be at the low end. Ask water company to confirm flow and pressure at their boundary box, pressure should be at least 7metres head.i.e. enough to...
  3. D

    Radiator 'whooshing noise'

    Any time, its just to see if its the gap within the valve thats creating the whoosing noise
  4. D

    Stock market dealing

    No idea what what MARA is ? is it a trading company? a supplier of candle charts or what. Tried to get my head around Notch 7 trading for dummied video but can't even work out what TradeNation site is all about. I assume all your charts you put up come from sites you have accounts with?
  5. D

    Radiator 'whooshing noise'

    Try fully opening the lockshield valve? Take note of how far its opened at the moment so if it upsets the balancing of the system you can always turn it back down to the original setting.
  6. D

    Ideal Classic FF250 issues

    Did you ever bottom this out or did you just end up getting a new boiler
  7. D

    How often do you injure yourself?

    Never had a bad DIY injury as such just the normal cuts, bangs and scatches as opposed to football/ rugby fractures but even though I was aware(ish) of cement burns totally ignored the factor when I was helping son to lay,spread/ tamp/trowel concrete slab until a several hours later legs began...
  8. D

    Will changing 15mm to 22mm increase flow rate?

    Typical 1st splurge due to force of mains pressure within the feed pipe that then reduces to whatever it does due to a constriction within the supply pipe. Possible cause of all your woes.?
  9. D

    gas boiler

    Exactly!
  10. D

    gas boiler

    Replaced a radiator and bled it, if that's your analysis of the situation you sound like cowboys with no idea i.e. was it a pressurise system that needed re pressurisation or a gravity fed system, did you just isolate the old and fit the new radiator.
  11. D

    Boiler Running Query

    Bang boiler stat up to 6 and see if that works in the short term but sounds like its time for a new boiler
  12. D

    Boiler Running Query

    And does this happen straight away or when the system has been running for a while and all the radiators are hot. Try putting boiler stat up a notch. I assume one of the radiators does not have a TRV setting so flow through the system is not blocked off completely at some point in the heating cycle
  13. D

    Will changing 15mm to 22mm increase flow rate?

    And has it made a discernible difference?
  14. D

    Fernox jointing compound on olives

    Reminds me of perps who always add more solder to yorkshire fittings :unsure:
  15. D

    Removing immersion heater

    Or he is lucky and immersion spins round due to initial torsional force, winners and losers
  16. D

    Removing immersion heater

    Surely as soon as you apply any force on a nut you are inducing torque???
  17. D

    Chimney Breast Vent

    yes
  18. D

    Fixing Loose Coving In Place

    I would drill 1/2" hole in the middle of the sprung coving, 1" from the end and then shoot coving adhesive into it so it fills in the back and also crosses over to the adjacent piece, then push the sprung bit back into place and secure. Securing is the hard bit but a couple of nails up against...
  19. D

    Fixing Loose Coving In Place

    Trying to squirt anything into a zero mm gap aint going to hold