Search results

  1. G

    Dry Rot

    hello, its a suspended floor and yes fitted units including some floor peninsula units with a dishwasher and washing machine and i cant see or smell or feel any leaks at least at floor level.
  2. G

    Dry Rot

    i have that familiar dusty smell in the house and want to cure it. but i cant find the source. Its a small red brick terrace - cavity wall. Its had a repaired roof this year after some leaks via the chimney, and its got a full width extension on the back, put on in 2016 - four years before...
  3. G

    Offcuts

    Thanks. I’ll pop them in, save a 15 mile round trip to the tip. Im maybe a little obsessed with the idea of water vapour at the moment!
  4. G

    Offcuts

    Hello Is it ok to put off cuts of plasterboard as sound insulation behind hardie board which will be tanked on an internal stud bathroom wall? I’ve got 25mm jablite in there already. or will they soak up condensation and go mouldy etc… apologies for full question!
  5. G

    Changing two way light switch

    Just to say Terryplumb is an absolute diamond. All now sorted. Thanks again mate.
  6. G

    Changing two way light switch

    I’ve reset it. Please try again
  7. G

    Changing two way light switch

    Okay. I’m in the north west.
  8. G

    Changing two way light switch

    No but a voltage sensor confirms there is power in all the wires.
  9. G

    Changing two way light switch

    Three switches. The top floor one first as it had the loose wire. And has only five wires not the six I was expecting. can you help?
  10. G

    Changing two way light switch

    No because top floor switch stopped working. Due to a wire that had come loose. The ground floor single switch works fine. The first floor switch to the first floor landing works fine. The first floor switch to the 2nd floor landing and the 2nd floor switch to landing and upstairs bedroom are...
  11. G

    Changing two way light switch

    Correct. The landing light also controlled by a switch the next floor down. At the moment that switch doesn’t work either. Im thinking that I need to flip the wiring on this top floor switch i.e. change out the l1 and l2s Should I also flip the L wires? basically turn it into a mirror image...
  12. G

    Changing two way light switch

    I’ve attached one with the right hand wires update as per the earlier advice. As you can see there are five wires, not six
  13. G

    Changing two way light switch

    So that’s given me power to the landing light but not the pendant in the room. is there not an issue with having five wires not six? and believe me I’m two months in trying to book an electrician to do this!
  14. G

    Changing two way light switch

    Got it. Thank you.
  15. G

    Changing two way light switch

    That’s exactly why I’m here. So are you saying I should move the com to where I’ve got it in the left hand connection to the one you’ve marked on the right?
  16. G

    Changing two way light switch

    Supplementary question Top floor switch is the end of this circuit and controls pendant light in centre of room and the landing ligh in the hallway outside that room Wire had become detached as I discovered when I removed the old switch plate But there are only five wires not the six I would...
  17. G

    Changing two way light switch

    That makes sense! Thank you
  18. G

    Changing two way light switch

    I’m changing a two way light switch in the hallway and want to be sure I’m doing it right. the old one - pictured is labelled common and has a horizontal layout the new one, also pictured, is labelled L and has vertical layout I’m assuming it’s a simple like for like with the two L1 and L2...
Back
Top