  1. ebee

    Plug in balcony solar UK , just a Lidl question

    It has not been thought out properly I think. As others have said the problems need ironing out. To my mind if it is allowed only if manufactured to a certain standard and/or to a certain method of regulation. I`m reminded of my little saying "Never ever ever ever buy from Fleabay". That does...
  2. ebee

    Water in bathroom pull switch.

    looks like there`s three conductors (wires?) i think we got to seperate them and "test " what they are before going further.
  3. ebee

    BFT Electric gate won't open - control units says STOP

    by "turning off" probably actually means removing all power rather than switching an off switch (although you might have aceived that anyway) leave it a few minutes anyway then "boot it back up" leave it for a few mins again then see if its different - rather like computersc and routers etc. As...
  4. ebee

    A missing friend

    Yes EFLI and Harry we all hope you are ok and some simple explanation of tinternet problems etc or you won the lottery and gone on a world cruise or something is what we hoping for
  5. ebee

    Octopus Smart meter.

    lol sailor vee ;)
  6. ebee

    Looped supply - power went off when DNO changed the meter next door.

    Yup it all sounds plausible radials, ring mains or whatever may be ok or not to add to . Only the DNO can tell. Us mere mortals can only see what we can see and estimate and assume what is what. On large estates etc the DNO might work to a figure of 2kw per dwelling or 3Kw each or something in...
  7. ebee

    Looped supply - power went off when DNO changed the meter next door.

    Well must admit I’ve not seen many looped ones either, well the look looped but unless you seen the next property they could be ringed instead. If you visit a looped property, it’s usually one looks normal and the other looks looped so you would likely only realise the loop possibility if you...
  8. ebee

    Possibly a Building Regs Question about Plinth Heaters??

    Yes I guess the original height dimensions prpbsbly accounted for bog standard baths and maybe even a bit more but none mounted unusually high due to long legs
  9. ebee

    Short bit of ceiling wire chasing

    I think you now have a list of alternative opitions - The one I would go for if I were you is to get a fitting that can more easily be wired using the existing holes, it ticks all the boxes , if you modify the units you have recently bought you might damange them, you will almost certainly...
  10. ebee

    Short bit of ceiling wire chasing

    unless you are accomplished or an electrician then lifting floorboards etc can be a little daunting for ordinary unaccustomed folks - on a few occaisions problematic for those used to it too. but yes it is a sensible consideration too.
  11. ebee

    Isolating Switch

    the most important thing to me is can it be stopped easily and readily by all all who might need to. if it is purely connected along with a fan and the whole lot together or separately can be switch off then ok. if its got timed overun or such then it needs to be capable of being switched off...
  12. ebee

    Possibly a Building Regs Question about Plinth Heaters??

    As an aside, ref the zones, the height of zone one and therefore zone 2 is purely from fininshed floor level but if the bath is mounted on a box then I think most of us would accept the place where the bath feet rest to effectively become the new finished floor level. But what size are presumed...
  13. ebee

    How do I go about this?

    Bonding has the potential (excuse that word "potential") to make installations safer, although it can also have the opposite effect of making things unsafer - a bit like the seat belt scenario, thought to predominantly improve safety yet under some conditions increases the danger. The outcome...
  14. ebee

    How do I go about this?

    LOL :giggle:
  15. ebee

    How do I go about this?

    Well, it is a good job that people do not talk about a system that includes the earthing (or grounding) of cars etc or else we would all need to drive around with straps of rubber stuff conducting from chasis to the road surface
  16. ebee

    How do I go about this?

    Well so long as nobody refers to them as a Ground Fault Circuit Interupter or something I think it might be OK ;)
  17. ebee

    Looped supply - power went off when DNO changed the meter next door.

    Yes it is not as uncommon as you might hope, with all of the services. Where I live a lot of the housing stockis sandstone terrace house built about 1910 mostly but a good measure over the years of other uildings of newer ages. The local council at the time used to supply the electrics before it...
  18. ebee

    How do I go about this?

    John yes we are in complete agreement on all of this, I am purely looking at the name we use to differentiate between the two devices as a sort of "starter for ten" rather than being technologicaly correct, I`m happy enough with the two terms Voltage Operated v Current Operated in this respect...
  19. ebee

    How do I go about this?

    Yep, i`ll not disagree with that John, in essence. What I was attempting was , what is the best (easiest) way to refer to them in comparison, loosley we calls the current operated (RCD like, comparing currents) or voltage operated (comparing voltages) as a ready distinguishable different kind of...
  20. ebee

    How do I go about this?

    Could we say that effective it is a rough attempt to compare two voltages 1/ being near true earth local to the installation and the other is the earth at the consumers earth bar, these will always be at different potentials wherever you go on this planet of ours but if we reckon it does not...