Search results

  1. D

    Beko DCU 8280

    Lot of steps in the youtube link not necessary. Guy is all over the place. If motor does not run, check the motor for continuity or rotor jamming Then proceed from there. Bit dangerous to handle live wires as shown n the video link.
  2. D

    Beko DCU 8280

    Yesterday removed the pcb and connected Fluke on wires to the pump at the pcb and ran the machine with clothes to dryer. Machine ran ok. Then removed the back to access pump. Connected fluke to the wires. Machine worked with 240 on pump, which again ran Suspect the sump must have been full...
  3. D

    Beko DCU 8280

    Refitted PCB Still getting tank full light and dryer stops. Signal from microcontroller energises a transistor to operate the relay. Going to solder wires to PCB at relevant point to see what is going on. If no progress will have to be a new tumble dryer. Thanks for reading the post and...
  4. D

    Combi boiler with rear exit flue in a kitchen base unit ?

    If it is not going to be serviced or repaired, ideal place to have it.
  5. D

    Kitchen sink waste merge two bowl wastes

    https://www.screwfix.com/p/mcalpine-1-1-2-bowl-sink-kit-trap-white-40mm/6295P?gclsrc=aw.ds&gad_source=1&gad_campaignid=19822796606&gbraid=0AAAAAD8IdPxsUmU4uG6Zsdr2jaxz5VLXI&gclid=Cj0KCQjw3qLSBhDaARIsAFTiVh7sy13S8tmUTlb41ciuykwRs3ZwpnWRg_e1xRf8avbO7sEst3Zds04aApdZEALw_wcB This one does covers...
  6. D

    This made me smile..

    What is Musk doing meanwhile with his excessive wealth Political and religious upheaval take many form
  7. D

    Beko DCU 8280

    Relay soldered onto the board. Coil resistance is tad over 700 ohms. Defect possibly the contacts are worn out switching inductive load (motor) Dare say can power the relay via external 12 volt supply and check contacts make, unfortunately the variable bench power supply is at friends house. Lot...
  8. D

    Beko DCU 8280

    Thanks for posting Float operates a microswitch. These sump indeed is full of water Relay is electromechanical not a triac The processor output switches the relay via interfacing transistor. Another sensor feeding into the processor causing the pump relay not to operate is a possibility hence...
  9. D

    Beko DCU 8280

    My own appliance Tank full light came on and dryer was not drying the clothes. Collector tank top left was empty Removed the condenser unit and flushed both ways Removed the back and looked at the pump gubbins- float was high up and operating the switch to display the TANK FULL led Removed the...
  10. D

    TACO Trump

    Looks like Taco name is sticking again.
  11. D

    17mm 1970 imperial 3/8” pipe fittings

    Stand corrected. Thought was a typo with that tape measure on it
  12. D

    Change from System and tank to Combi

    Secondary return pump is essentially required for larger properties that have remote hot water requirements. When this tap is run, there would be significant delay before hot water gets there. A hotel is a prime example= hot water on tap is quite quick to arrive. Combi on the other hand is...
  13. D

    Change from System and tank to Combi

    Secondary pump on an unvented cylinder NOT a combi boiler OP has a heat only boiler and cylinder.
  14. D

    Vaillant ecoTEC plus 418 VU GB 186/2 OH - Error codes F62 and F22

    :ROFLMAO:. If a heating engineer like Countryfan missed number 418 is not an heat only boiler ( ie not a combi- which would start with figure8) then he must be having a very bad day. Also, a system boiler would start with digit 6 and would be sealed BTW. Countryfan works with these boilers...
  15. D

    Worth a laugh

  16. D

    Change from System and tank to Combi

    Fitting a secondary pump gets over the issue of delayed hot water at the tap First heat only boiler I looked at, a Glow worm minimum is 4.5kw Sure Vokera will beat that turn down ratio
  17. D

    Change from System and tank to Combi

    Regardless of the brand, it is paramount that the boiler gets proper service instead of brand as every boiler is there to do the job. Some are better built making service a comfortable task, others are like a pigs ear and service is a pain. Know from experience as I have boiler hitting 40 year...
  18. D

    Blank Display Ideal Esprit 2

    The display illuminating suggests low voltage present but display activation ( segments that align to create the information, not being addressed) Perhaps the display pcb if it has one? Else like above post the main pcb
  19. D

    Will Iran and the US reach a long term cease fire this weekend?

    Need not worry, Taco will chicken out
Back
Top