  1. W

    Build over agreement rejected?

    Something doesn't add up here. Initially the OP was saying "as the extension will be over the top of the existing sewer manhole" They then went on to say the sewer is about 2 m deep and the builder had dug a trench from the manhole in an attempt to trace the drain run. Why not just look down the...
  2. W

    Ventilating a damp cellar

    If only the parts of the wall that are tanked are suffering from condensation don't you think that is suspicious? I suppose it could be a coincidence that the tanked areas are colder and that is why you are getting condensation but I would investigate whether the tanking has failed. I am...
  3. W

    Ventilating a damp cellar

    We have had a prolonged hot dry spell of weather so condensation is less prevalent at the moment. What does the tanking consist of? Is it possible that the tanking has failed and it is minor penetrating damp rather than condensation? If it is condensation is there an effective vapour barrier on...
  4. W

    Room SIze Standards - Living Rooms

    Don't forget that the National Space Standards you quoted in post #4 have minimum gross internal floor areas which has implications for the other habitable rooms such as living rooms, I've been caught out by this before. So whilst there are prescribed minimum areas for bedrooms the other...
  5. W

    Wood vs. Steel for Dormer Loft Conversions: A Debate with My Architect

    The drawings just look very sparse and sloppy. I guess they are the planning drawings but even so there is a complete lack of any annotations, except the size and position of the radiators which is rather bizarre. Also the floor plan shows a small window on the rear dormer cheek but not shown on...
  6. W

    Wood vs. Steel for Dormer Loft Conversions: A Debate with My Architect

    Reading your response to what I assume is the particulars of claim there is one glaring error in the designer's evidence. I cannot see any reference to a written fee quote or confirmation of their conditions of engagement. Nor can I see any reference to a written instruction from yourself. That...
  7. W

    Issue with neighbour over 'party wall'

    I totally agree with your advice but I would just add that I took a closer look at the photo in #26 and the neighbours "lean-to" actually looks like it is freestanding structure not attached to the OP's flank wall. It appears to have freestanding support posts so possibly not a Type B party wall...
  8. W

    Issue with neighbour over 'party wall'

    The water has been further muddied by the neighbours lean-to. Even if the disputed wall is on the OP's side of the boundary the fact that the neighbours have enclosed it with the lean-to roof could potentially make it a party wall. I confess that I don't know if a ramshackle lean-to would count...
  9. W

    Issue with neighbour over 'party wall'

    I think the problem here is that the OP served notice when he didn't need to. The wall in question clearly isn't a party wall so I can only assume that the notice was served because of the excavation for the trial holes to investigate the existing foundation? Now that the OP has opened the can...
  10. W

    Permitted development dormer

    49 cubic metres for the dormer AND the hip to gable? It is quite a tricky calculation and from the photos it looks tight. Also I have to confess I don't know if an end of terrace is treated as a terraced house or a semi-detached. Hopefully someone cleverer can confirm. Otherwise, assuming the...
  11. W

    Permitted development dormer

    If the designer drew plans to ensure the work was permitted development and it subsequently turned out that the work was not PD then the designer has got some explaining to do! I would say that he is also legally liable for any costs you incur to resolve the situation with the planners. No...
  12. W

    Permitted development dormer

    If the planning consultant says it is PD and they have seen the drawings (unlike us) then submit a lawful development certificate application. Out of curiosity why did the designer who submitted the planning application say it wasn't PD. Simply being above the outrigger does not make it not PD...
  13. W

    Permitted development dormer

    I'm confused. How can a terraced house have a hipped roof and how can a "rear double extension" be original? Either it is an extension OR it is original. You mention an outrigger is that what you meant rather than an extension? To the best of my knowledge you can build an L shaped dormer on the...
  14. W

    Digging Footings before Building Regs?

    That's a first for me! No risk of a conflict of interest there then? Normally if you submit a full plans application you are allowed to start work before approval but any work is done entirely at your own risk. The building inspector will still come out and inspect the foundations. What don't...
  15. W

    Porch within 3m square

    This explains the difference ..... https://www.labc.co.uk/homeowners/what-type-building-regulation-application
  16. W

    Digging Footings before Building Regs?

    Is this a new build dormer bungalow? Can you do that on a Building Notice? Why is the private building control company drawing the plans? Normally they just check the plans? Normally if you submit a full plans application you are allowed to start work before approval but any work is done...
  17. W

    Porch within 3m square

    The cloakroom WC/shower will need a wash hand basin. The internal wall is suspiciously narrow. I don't think you will get a 250mm thick external wall to meet the insulation standards. Also I think you might be mixing up Planning Permission and Building Regulations consent, Woody mentioned both...
  18. W

    Porch within 3m square

    I don't see how you are going to squeeze a cloakroom WC and entrance lobby in a space 1.74 x 1.55m? Rather than compromise the design for the sake of avoiding planning surely it is better to design something that provides the space you need?
  19. W

    Best Grinder Blades For Paving Slabs

    I think you're spelling it wrong, it should be Grindr. Apparently the 9 inch is much more popular! ;)
  20. W

    Recurring Stability Issues with Brick Piers

    D'Oh! I completely missed that. That blows my theory out of the water.