  1. G

    Baxi 105e the 60 degree light flashing

    draindown take off the pump pressure switch housing 4 screws clean and grease the pin change the diaphragm and below the diaphragm is a tiny hole that gets a wee bit of crude in it clean this out by using the pin attached to bearing plate. . edit ignore wayner he is right its not his area
  2. G

    Lead gas feed

    You wouldnt have to renew anything coming into the house as that has already been done . The lead outlet could possibly have been slightly altered by bending it to get a fitting on it that would allow either a wall or floor bracket to be fitted . But it is probably meter changer company policy...
  3. G

    Lead gas feed

    can you take a picture of meter Sounds like a meter monkey getting out of a job
  4. G

    Moving a radiator with chipboard subfloor

    Ditto out of all my rads i have got 5 of the oval tubed double paneled ones in my house and they get there respective rooms up to temp very easily with loads to spare . And of the dozens i have fitted i have never had a cust say the room is not getting to temp. radiatorking.co.uk is a good...
  5. G

    Cutting redundant small bore copper pipe

    if you have one Use a 4 inch disc cutter with a 1mm disc it will sail through it
  6. G

    Type 22 vs Type 21 radiators

    lol common sense would say it should be a k1 if double double is k2
  7. G

    Type 22 vs Type 21 radiators

    New rads are thinner metal than old rads so heat transfer is quicker
  8. G

    Type 22 vs Type 21 radiators

    K1 is single panel rad with fins not a 21 double . P+ is a 21 ;)
  9. G

    de-soldering - unsuccessfully

    with water in it , it must be north sea gas ;)
  10. G

    de-soldering - unsuccessfully

    yep , when there isnt any room get a big hacksaw blade wrap abit of duct tape on it to hold and the do the best to cut through it with small strokes obviously as pros we will have multitools / reciprocating saws but have used just a blade many a time
  11. G

    Glowworm £350 difference!

    you can pay hundreds more for couple of years longer warranty
  12. G

    de-soldering - unsuccessfully

    Although water is the usual cause it is Not unusual for fittings to not come off it may have been really tight before even being initially soldered
  13. G

    Drilled a gas pipe

    Christ know why anyone would suggest a complete re run for such a basic repair
  14. G

    Grundfos UPS 15-50 pump intermittently trips MCB/RCD – repair or replacement?

    https://www.wolseley.co.uk/product/archergas-st15-heating-pump-15-60-130-new/?srsltid=AfmBOopik0fYQ3H1HS0gl7MnvdiE7RSbC2R0WoGPRkETorNH7UiwKFe3
  15. G

    Combi with hot water tank - no HW

    pretty certain the top one is HW you can see the pipe going to cylinder
  16. G

    Imperial pipe bigger than the norm

    Clean inside of pipe and get a 12mm to 15mm adaptor stick the 12mm end into pipe and solder it in
  17. G

    Isolation valve leak / weep

    Plastic threads ? Or brass
  18. G

    Solder fittings to boiler

    Wont harm it in any way done thousands like this with no ill effect
  19. G

    Dripping kitchen tap

    https://www.toolstation.com/search?q=tap+reviver
  20. G

    Recommend a boiler

    i think what he is really asking what is cheaper