Search results

  1. H

    Oil advise please

    Thanks for feedback really appreciate it mate !!
  2. H

    Oil advise please

    Evening all hope everyone is well, just want some advice regarding oil fault finding. Been told I’m going to be fault finding on oil boilers in my area there are a few grants but mainly Worcester,some new but mainly the older models. I’m going to get my self booked on a few courses with the...
  3. H

    VAILLANT ECOTEC637

    Easy job get Vaillant out and replace faulty mass flow sensor as this is keeping it in comfort mode, common on these easy job
  4. H

    Valiant Ecotec Pro boiler making strange noise (video£

    Easy fix divertor valve needs replacing, as bypass rattles need a gas Engineer to sort though hope this helps
  5. H

    Boiler flu sounds like a gurgling drain!

    Likely to have damaged many parts you have 2 options either gas safe engineer to fix or pay ideal to fix boiler, as non boiler fault Good luck
  6. H

    Potterton ProMax Combi - Flush and Clean Sludge (micro-bore system)

    Totally agree with baxi engineer as if he doesn't advise you of the issue, then if fails in the future which it will you can't blame the boiler, not anyone's fault but system issue giving grief, feel for you. But all manufacturers/him serve/domestic and general etc clearly state if any...
  7. H

    Viessmann Vitodens 200

    When changing over we to constant controller you have to adjust a few settings otherwise it won't work Good luck
  8. H

    Glow worm 18hxi wiring help.

    There will be a connection in the wiring centre as on the hxi it has its own pump connection get a sparky to sort out will be best thing
  9. H

    Leak from solar panel pipework

    With solar you have to be on the ball, seen some have a go heros that made a cylinder inpload , but not all engineers are aware of solar regs etc. Atleast going to a manufacturer they will send some one competent (you would expect!?!) but don't mess with it yourself Good luck
  10. H

    Homeserve boiler problems.

    Get a ferroli in there can't go wrong there doing a 7 year warranty and a bucket with all ranges
  11. H

    Ferroli Modena anyone had one fitted in/around 2015

    I know they make a Big Bang noise every now and again but ferroli can't explain why or how,its not explosive ignition , sounds like water flow noise banging but can't sort, what you had
  12. H

    Ideal mini c28 on/off

    Could be pcb issue depends on age of boiler etc, could be stray voltage from external controls, could be a number of issues, get a gas safe guy in to look at issue Good luck
  13. H

    low cost combi Boiler Reviews

    Go for intergas rapid cheap price can be used for heat only/system/combi no brainer for the price just needs a strong wall to be fixed On but can't fault the rapid
  14. H

    Glowworm boiler - keeps tripping showing F5, F9 or F11

    Likely to be pressure sensor/ heating vessel flexi hose get installer back to investigate, no chance of a diy fix im afraid Good luck
  15. H

    New Vailent ecoTec exclusive Green - how does it compare?

    If it's the new Vaillant iq you need a min of 11 Liters per min to fully test, nightmare to repair in the future due to internal pipe work lay out, went on the course and didn't seem impressed!!
  16. H

    Vaillant ecomax 828/2e hot water problem

    Difficult to fully clean plate heat exchanges, if heating fine either divertor not moving over fully or plate blocked, had the same for a customer last year thought I clean plate out but since I changed it all sorted Good luck
  17. H

    Boiler losing pressure only when heating is off

    Likely to be either leak on pipe work/system or main heat exchanger is passing and leaking down condense run, I've had quite a few main heat exchangers pass, hope this helps good luck
  18. H

    how long to service a gas boiler

    Depends age of boiler some require a combustion reading before stripping down parts within boiler. Gas rate and working pressure should take min time depending where gas meter is etc. Check of flue and visual inspection of aav/ hydroblock for any leaks or noises. 25/45mins is about right. Older...
  19. H

    Vaillant grinding sound inhibitor

    Any updates John as my customer has something similar Thanks
Back