Search results

  1. H

    Hot water turning Luke warm from boiler

    Think about the flow and return pipes to main hex,oxide sits nicely in hoses and if sqaushed it will fall into plate hex after a little while. Had loads as engineers squeeze to make work which is naughty!!
  2. H

    Hot water turning Luke warm from boiler

    Cpuld be that the engineer squized the flow or return hose and a lump of oxide got into plate
  3. H

    Vaillant Ecotec Plus 430 Open Vent - Pump Overrun - Required?

    It says you dont need pump supplie,/no perm live
  4. H

    Hot water turning Luke warm from boiler

    Poor circulaation though plate hex,could also be blocked rubber hoses
  5. H

    Vaillant Ecotec Plus 430 Open Vent - Pump Overrun - Required?

    Hi i will tell you now that you must wire pump at boiler , i know it says not required but i fitted a glowworm energy which is the same heat ex and design, didnt wire pump to boiler which meant it overheated regually. engi eer came out and said run pump wire to boiler to sort as soon as i did...
  6. H

    Ideal logic plus combi 24kw

    Good shout about foam nice and easy fix
  7. H

    Ideal logic plus combi 24kw

    Remove gauge and fit icons/isar gauge as hole is different size,that's all I do
  8. H

    Vaillant Eco Max 824E - Very slow hot water flow

    Check if you have scale reducer on cold by boiler as I have seen loads cog up,or check cold supply to boiler isn't cogged up. Also cut hot pipe under boiler to see what pressure is like.hope this helps keep us all posted
  9. H

    Boiler not working after short use

    Over heating issue maybe but pay the manufacture to sort unless you have a engineer that is happy to work and fix these boilers. I'm not a fan as they leak all the time and cut your hands changing parts Good luck
  10. H

    Vaillant main heat exchangers

    Thanks I was going to fit machine straight on flow and return I've got an immersion heater as doing any flush cold is a waste of time. Thanks for feedback
  11. H

    Vaillant main heat exchangers

    Hi people hope all well,maintaining a number of boilers and got a vaillant heat hex kettling as I have sorted system out but just wondered if I can clean main the main hex? Due to the micro bore style water ways I'm unsure if it will bypass or if can soak with liquid or use fernox ds40. Any...
  12. H

    New vaillant ecoplus boiler and really fed up

    Sounds like it was wired up on switch live ,ESP if you had to run new wire,get the wiring checked as this doesn't sound like a boiler fault,,boiler will only come on if a signal is sent from controls.sadly not all engineers can sort heating wiring,but don't get to stressed with boiler.good luck
  13. H

    New vaillant Eco tec pro

    Thanks just had reply from bunnymann,is it fitted to a tee style fitting as it looks in the book internal hence why I asked if it was the same fitting?
  14. H

    New vaillant Eco tec pro

    Hi just wanted to see if anyone could confirm if the low water pressure sensor for heating on the new Eco tec pro is the same as the heating low water pressure sensor on Eco tec plus etc,the reason I ask is I can't find the part number as looking in the book it's on the return by the heat...
  15. H

    Baxi Megaflo 24HE boiler Central Heating constantly ON

    Get your electrician to check switch live/heating wires in wiring centre if you have an rf stat it may be sending voltage back even in off position,due to the relay in reciver.
  16. H

    Blocked central heating.....not one rad working

    If it was me get the guy back who done power flush get an immersion kit set up and cut in to flow and return pipe work --- this removes the need for the boiler. I just don't understand why people flush with out immersion as it confirms proper heat to a rad. I my opinion flush cold is like...
  17. H

    Heatline Vizo 24 BAR light flashing and very noisy

    There should be a copper pipe out side see if it drips maybe expansion vessel needs pumping up and pressure relif valve replacing?the boiler could be running dry
  18. H

    Fault-finding central-heating wiring

    Looking at wiring centre what is the wires going into terminal 1?also with so many blues surely it needs sleaving on them to work out what is what?
  19. H

    Scale reducers for intergas

    Hi team hope all well I will be fitting some intergas combis and just confirming what to fit on the cold side for scale prevention as I'm on the south coast, I am thinking of putting a tee and valves on he/cw so in future if it scales up I can clean boiler circuit. As I'm not 100% on the inline...
  20. H

    Second shower with a combi..best to go electric?

    I always state a electric shower if it's an ensuite/second bathroom as at some stage a combi not matter output will fail atleast you have a back up for hot water and also very easy to replace if they fail. Don't put all eggs in one basket