Search results

  1. H

    New Atag boiler

    Just seen the advert in gas magazine for new Atag boiler not sure how this is going to work,as I called the office in Chichester and it's completely different company even though same web site.the spells disaster all round surly. I have just started fitting the 325ec range but unsure over this...
  2. H

    Replacement Gas Boiler

    They are an ok boiler make sure you have a pressure reducing valve to make domestic water balanced;and engineer reduces she vessel to 3bar as they come out the factory set at 5.5 bar,also fit a flow regulator at 18lpm on the hot pipe under boiler and just make sure system is clean as the rubber...
  3. H

    Replacing a Vaillant boiler

    Hi not sure weather your heat exchanger will be the same as the new vaillants, I find the water ways on the vaillants/glowworms/Ariston/ravenheat are like a batch of micro bore pipe and tempremental to cleaning if dirt finds it's way in. Ali heat exchangers are poor in Worcester and ideal,I...
  4. H

    Sludged up heat exchanger - replace or flush?

    If it's stainless steel it doesn't need to be replaced,just clean.I have never replaced a steel heat exchanger,good liquid or powder does the job,I find if on immersion rig main heat exchanger or blow torch to heat chemicals on a plate hex is good enough.
  5. H

    new boiler which ?

    I haven't fitted an intergas as yet as I used to fit branded boilers (driven by customers) but now I would fit atag if I get the say so,to be honest hard water isn't that much of an issue,the condense pipe was standard overflow pipe,if it was going into a soak away I would fit an air break...
  6. H

    new boiler which ?

    Like others have said intergas are simple, I used to fit main stream brands customer driven but I went to a mates the other week and he had a atag with gas saver combi only and it was very impressive , bit bigger then then the kitchen cupboard size, anyway I fitted one on a new install and was...
  7. H

    new boiler advice

    I don't think so with a combi you would need an open vent/heat only boiler with buffer/thermal store set up.get advise from plumber who you will use
  8. H

    new boiler advice

    Hi I have just done swap from electric heating to gas as a meter and supply pipe fitted to property, I used to fit mainstream brands of boilers but I saw at a mates an ATAG with gas saver which meant he got 15lts per minute at 35* rise for a 30kw boiler which is fantastic. Any way I swapped the...
  9. H

    Ferroli domi compact F24b hot water sensor

    Its either going to be a blockage in a part in the boiler as high temp rise can't get through heatexchanger or sensor is out of calibration,the other thing to see is make sure the flow through taps is good as so tap washers/jumpers drop =reduces flow rate boiler cuts out Good luck with the...
  10. H

    Ferroli gas CH boilers

    I thought there new boiler was meant to be the saving grace ?? I used to fit a number of well known branded boilers but as any boiler has issues with it's how the company deal with the situation. I find that it can be hard work which is a shame,as I put on other thread I went to a mates place...
  11. H

    Worcester Greenstar 42 cdi,New version!!!

    A number of boilers fail on day one,it all depends on how they act to work it out and look after you,had one the other day where plate hex needed to be tighten up,another brand boiler ran for 3hrs then wouldn't work pcb didn't detect the flame,also a 4week old boiler the gas valve seized...
  12. H

    Atag boiler

    Hi Lee sad to hear that, a number of my Customers have had parts replaced on ideal logics/Viessmanns ie gas valves/pcb/chattering diverters/burner Issues all under warranty and sorting out with other manufactures customer service has been harder then it should be. Be interesting to no what you...
  13. H

    Atag boiler

    Dan thanks for the info and great pics I will get on the course and where possible I will fit the atag range in the future. I wonder when and what the other atag brand will be like
  14. H

    Atag boiler

    Yeah your right about training , I just cant understand that they can't get the output for hot water on temp rise for the model that has the vessel on the side,that way it could fit in a kitchen unit, dan have you had any issues with them ie noise/electrics/leaks etc the reason I ask is if I...
  15. H

    Atag boiler

    Seems good feedback,thanks guys it's a real shame that they don't have a kitchen cupboard size boiler,the looks of the boiler don't seem that much of an issue for my mate,as the door covers it,but even in kitchen it's usually got a door covering it,as long as it's quite and works well, it ain't...
  16. H

    Atag boiler

    Seems good feedback,thanks guys it's a real shame that they don't have a kitchen cupboard size boiler,the looks of the boiler don't seem that much of an issue for my mate,as the door covers it,but even in kitchen it's usually got a door covering it,as long as it's quite and works well, it ain't...
  17. H

    Atag boiler

    Hi dan I was in the plumbers merchant and overheard that a new model is coming out,the trouble is it's a franchise and sales reps have been employed by this franchise for some time with out any info of the boiler,also naming the new boiler as it's 2 different companies so branding will...
  18. H

    Atag boiler

    Hi dan I was in the plumbers merchant and overheard that a new model is coming out,the trouble is it's a franchise and sales reps have been employed by this franchise for some time with out any info of the boiler,also naming the new boiler as it's 2 different companies so branding will...
  19. H

    System separation

    Hi guys hope you all well I have been asked to fit a system boiler on an oldish system but am thinking of having it as a spit system using a plate heat exchanger to have the boiler side pressureised and keep the system side tank feed,as oldish pipes under floors.i want to use an atag but there...
  20. H

    Atag boiler

    Hi guys thanks for feedback I would seriously consider fitting them in the future,as they seem a nice bit of kit. Can you use a standard rf control on the boilers Ie honeywell/drayton/danfoss etc ,if so is it low volt or ok 240vac? Great photos dan really nice! :D
Back