Search results

  1. D

    Reverse Circulation when HW On

    There are a few different ways to put the pipework in order. 1 check valve is fitted and it requires 2 further one to overcome the system flaws. We still have no answer to my last question re the noise problem
  2. D

    Towel rail question

    Or fit a trv and then easy to turn on/off and to a large extent it will do that itself. Lag it with towels and it will give out very little heat.
  3. D

    Reverse Circulation when HW On

    Do it properly or go the check valve route.
  4. D

    Worcester Greenstar 25si Boiler issues

    What fault code does it show?
  5. D

    Reverse Circulation when HW On

    Definitely not 100% solution.
  6. D

    Reverse Circulation when HW On

    But not in the summer or when room stat is satisfied.
  7. D

    How to remove valve in shower

    Pull the white plastic off. Some are held with a grub screw through the body so run your finger around to feel for a hole. Otherwise they are screwed in. You will need the water off to avoid excitement.
  8. D

    What do you think? New boiler required

    Stick your part no. in the search box here. They buy new boilers and strip them down https://ukboilerbreakers.co.uk/product/worcester-87161157410-main-heat-exchanger-gc-no-41-406-47-2
  9. D

    How to unscrew this kind of tap?

    Oh yes in one photo the screws are gone. I would have loosened them and then you have something to put your finger and thumb on to spin the nut. Grips can be used but probably not required. Threads look nice and clean.
  10. D

    How to unscrew this kind of tap?

    Loosen the 2 screws and the nut will only be finger tight
  11. D

    Reverse Circulation when HW On

    Chatter that you can hear if you put your ear to it or from the bottom of the garden?
  12. D

    Reverse Circulation when HW On

    With T. Rail off and 1 up rad turned to max.does it still chatter ?
  13. D

    Reverse Circulation when HW On

    What type of check valve is it and are you all thermostatic rad valves?
  14. D

    Hot Water Running Out

    No, the pipe to shower head is irrelevant. No idea what showers you have, ideally it would be a bar shower mixer but it could be fully concealed with only push buttons available or an electronic one below bath. You may also have blending valves (tmv) fitted to wash basins or bath and a fault...
  15. D

    Reverse Circulation when HW On

    With your check valve in place this is as expected. If you fit a check valve to t.rail circuit all should be well but t.rail will then only come on with heating. If you can move the t.rail flow to anywhere between the pump and the 2 diverter valves you would have all year round operation and...
  16. D

    Reverse Circulation when HW On

    Its panto season so Oh no I didn't
  17. D

    Reverse Circulation when HW On

    Turn the towel rail off and I believe that everything will be fine. Let's start from there.
  18. D

    Reverse Circulation when HW On

    If there is a circuit there will be circulation. If you read again my last post it explains why towel rail reverses when hw on. It also flows through all of the radiators in the right direction. If you turn the towel rail off on your diagram you can then see the alternative route, backwards...
  19. D

    Hot Water Running Out

    Run a shower on hot till the body is nice and hot. Turn off shower and open a cold tap. Cold running through shower valve will rapidly cool the shower body. The faulty valve could well be providing a secondary loop, circulating on gravity, which would deplete the hot water store.
  20. D

    Reverse Circulation when HW On

    Or fit a check valve to towel rail circuit and towel rail will work only with ch
Back