  1. D

    Heating not going off on timer

    Put your pump on 3 Did you Turn cyl stat down, valve moves to H and heating pipe should now be getting hot? If not, remove head from valve and turn the spindle manually. You should be able to divert the heat to water or to rads.
  2. D

    Heating not going off on timer

    Again crossed posts, I am beginning to doubt that your pump is running. If it has a big screw in the centre removing this, there will be a bit of water so have a rag handy, you can put a screwdriver on the end of the spindle and feel if it is spinning or help it to start
  3. D

    Heating not going off on timer

    Spindle only turns 90 degrees so not possible and head only fits in one position. Turn cyl stat down, valve moves to H and heating pipe should now be getting hot? If not, remove head from valve and turn the spindle manually. You should be able to divert the heat to water or to rads.
  4. D

    upstairs bathroom existing soil pipe alteration advice

    https://www.google.co.uk/url?sa=t&rct=j&q=&esrc=s&source=web&cd=1&cad=rja&uact=8&ved=0ahUKEwjr_-f-sI_ZAhWKDsAKHXglBI8QtwIIcTAA&url=https%3A%2F%2Fwww.youtube.com%2Fwatch%3Fv%3D4CWtom0IFmQ&usg=AOvVaw2Qz2LBZP24V5zgk_gTgQOl
  5. D

    Heating not going off on timer

    Mine and yours were posted at the same time. Your boiler is firing then, any heat at pipes by diverter valve? Any heat at pipes by boiler? Diverter is behaving as it should isn't it?
  6. D

    Poor pressure from new shower

    If your hot is restricted flow then blanking the cold and testing the hot on its own would have shown this
  7. D

    Heating not going off on timer

    Do you have a blue light on the boiler?
  8. D

    Showers gone luke warm?

    No they are tank fed
  9. D

    upstairs bathroom existing soil pipe alteration advice

    You can get a slip socket (or grind the stops out of an ordinary push-fit socket). This will slide all the way on to 1 section, then line up the other section and slide to be half & half. I usually fit a clip below to make sure it can not slide down. Also handy to get a clip to support so that...
  10. D

    Showers gone luke warm?

    Do you have other hot taps supplied by this cylinder and if so do they run OK? Could a bit of fibreglass etc have got in to the tank? Could you disconnect one of the hot pipes and put a hose on it and confirm that full flow is available on the hot? Drop shower head in to tray and run shower...
  11. D

    Insufficient flow Hot Water from Unvented Cylinder

    The hot water outlet from the cylinder can get quite choked so worth a look in there
  12. D

    Poor pressure from new shower

    Was this at hot and at cold individually or simultaneously or was only cold tested ?
  13. D

    Heating not going off on timer

    Power off. Put link from L to w.on and from w.on to h. on. Power back on room stat and cyl stat up valve should be mid position, pump & boiler running, rads & water heating. Turn cyl stat down, valve should be H, pump & boiler on & rads heating Turn cyl stat up & room stat down, valve should be...
  14. D

    upstairs bathroom existing soil pipe alteration advice

    Where the waste is (was) connected in to the soil pipe, the fitting on the end of the waste pipe is a boss adaptor which should be glued in to a pre-formed boss on the branch. Yours has been glued in to a hole cut in the side of the branch, no good at all. I would now describe that branch as...
  15. D

    Showers gone luke warm?

    OK got it. Senior moment
  16. D

    Showers gone luke warm?

    He has checked and hot pipe at shower is "very hot"
  17. D

    Showers gone luke warm?

    You did clean the correct filters? There are 2 pairs of filters for different inlet configurations. Only 1 pair is in use
  18. D

    Heating not going off on timer

    Have you put the clock back on?