    Downstaire lights trip since house earth spike installed

    So what you are now saying is despite slagging off your 1 month wonder which by the way doesn't make him an electrician it could now be your fault due to your incompetence and stupidity, it beggars belief
  2. Y

    Heat alarm lifetime/replacement

    or it has been sat on the shelf in the shop for 6 years prior to been bought!
  3. Y

    RCD Keeps tripping, may be 8.5 kW Shower?

    Your 40amp not mA as you keep saying is ok for an 8.5kw shower, it sounds like you have a cabling issue and that's what needs testing between the db and switch and switch to shower Beaten to it damn!!
  4. Y

    Does this switch have a fuse?

    This guy is a knob, why are we bothering answering his questions - at least when it goes wrong all the other residents know who to blame!
  5. Y

    pscc of breakers

    If your on the domestic installer scheme why are you getting involved in commercial work? If your pretty highly qualified why are you asking questions on a DIY forum and it's not a fairly unusual situation, your just out of your depth. If your qualified why do you think it could be against...
  6. Y

    Please help me assess my wiring/heating

    The red one from meter to joint, if too tight fit it onto the grey with the loop next to the one it's on already
  7. Y

    Please help me assess my wiring/heating

    The problem stems from the fact you have a single pole Henley block with all lives joined together, that mains board has 4 tails 2 live 2 neutral and one half should be switched by the teleswitch, this is not happening you need a competent spark to sort out for you. Btw you have the sensor on...
  8. Y

    Trailing edge dimmer and weird squeaky noise.

    Have a look at fitting these :- http://www.ledbulbs.co.uk/products/MR16+%26+MR11+LED+Bulbs/Dimmable+MR16+LEDs/Philips+4W+MR16+Master+LEDspotLV+Dimmable+Lamp+-+24+Degrees+(Warm+White)/1833294623 We have fitted hundreds of these and as they work with existing fittings / dimmable transformers...
  9. Y

    Courtesy load v.s Security load? - PIR wiring

    Look at the instructions properly, it clearly shows two lamps 1x dim and 1x bright so you need two fittings or a dual lamp holder fitting ffs its not rocket science. leave it to someone who knows what they are doing.
  10. Y

    Light switches puzzle

    so lets have a look :- 1. no red sleeving on yellow/blue conductors 2. too much copper exposed on switch terminals 3. conductors cut bit too short for my liking 4. no sign of any earth sleeving on 1st picture 5. no intermediate switch fitted 6. different makes of switches fitted so will...
  11. Y

    one for westie101 to advise

    yes they have, its not our install but our site so been nosying at the quality of the cable terminations etc
  12. Y

    one for westie101 to advise

    We do work for a national hotel chain, can't name but will become obvious with rest of post. basically have a 400a tpn pme supply and runs at approx 180 - 200a normally, but they have now had permission for a big wheel attraction which is now up and running, what i'm asking is as the wheel...
  13. Y

    is putting in a temporary consumer unit fraud?

    that sounds like he's connected a 6way trailing lead direct to the incomer! can you post a pic please as a side issue if the supply is pme and it's a 'temporary supply' should it have an earth rod installed and pme earth not connected
  14. Y

    pop rivets to fix surface mount boxes.

    only prob i can see is apart from as you state being a pig to remove, that the final snap of the riviting tool could snap/crack the box, then again could be ok with penny washers fitted.
  15. Y

    When a 13A SFCU just will not do!

    blimey! just shows there are no limits to the depths of bodginess that 'electricians', diyers or the damn stupid will go to!
  16. Y

    Blowing Fuse Wire

    yup nothing to worry about, rewireables (bs 3036) are covered in the 17th edition so perfectly acceptable, just annoying when they blow!
  17. Y

    Lazy cowboy sparks and 3phase don't mix

    it's not marked up but believe it could be either the leisure club Db or leisure plant room Db we are starting a 100% test of hotel soon so will no doubt trace it but makes you wonder about the installs quality
  18. Y

    Lazy cowboy sparks and 3phase don't mix

    Came across this yesterday when inspecting something else, i know federal mcb's arn't cheap but who bolts 16mm swa direct to a 200a 3phase busbar! 1. board view 2. busbar view 3. m4 bolt mcb!! and yes there are no blanks so fingers can touch all 3 phases - nice