  1. M

    Heating and hot water digital programmer

    Mines a fully pumped system installed in 1996. It originally had a heat only boiler but we now have a system boiler installed in 2015. The main pipework is 28mm and the pipework to the radiators is 15mm, i dont know what happens to the pipework under the floor.
  2. M

    Heating and hot water digital programmer

    My boiler flow and return pipework is 28mm so not unusual.
  3. M

    Heating and hot water digital programmer

    You must have two motorised valves, the wiring looks like an s plan.
  4. M

    Trv identification

    Its a Honeywell valve body, same as mine.
  5. M

    New Vaillant install - are the Vaillant controls worth it?

    If your friend replaces the Vaillant controls with Hive it will be a big downgrade. Have a look at what Hive can do, it’s not much other than turn the boiler and on and off.
  6. M

    Smart TRV's, advice on set up

    Are you planning on keeping the existing boiler controls and just installing “smart” TRV’s to act like standard TRV’s?
  7. M

    S-plan or PDHW with replacement system boiler

    As I understand it from online posts it can be a right pain in the a*** to get DHWP to work with Viessman boilers due to the demand box requirement. There is a good thread on the Buildhub forum.
  8. M

    Dual heating control setup - Honeywell Evohome plus another brand for smart TRVs?

    How well insulated are your rooms? Heating individual rooms can make the heating less efficient as the cost to heat one room is not necessarily cheaper than heating multiple rooms. Unless the unheated rooms are very well insulated they will just suck the warmth from the heated rooms resulting in...
  9. M

    Method or madness in this CH installation?

    The diverter valve I can understand, I thought the OP was talking about a motorised valve as in a Y plan system.
  10. M

    Carbon Monoxide Alarm

    Flame on a gas hob are normally blue.
  11. M

    Method or madness in this CH installation?

    What’s the purpose of the 3 port valve, Combi boilers don’t normally have motorised valves at all.
  12. M

    Trv valve off but radiator not cooling down

    Maybe a silly question but you are turning them clockwise to turn off?
  13. M

    Bang when central heating shuts off

    Pipe work not secure somewhere is possible.
  14. M

    Has wrong kW rated boiler been fitted

    There should be a label on the boiler stating the model and GC number.
  15. M

    Should I replace my ideal Mexico super 2 boiler with a heat pump

    It’s very likely that you will need not only the heat pump but also a new hot water cylinder, all radiators replacing and pipe work modifications so expect the HP bill to be a lot more than just a gas boiler replacement.
  16. M

    Draining an indirect cylinder to change a faulty zone valve

    Is it the valve sticking in the valve body or the motor sticking in the valve head? If it’s the valve head then that can be changed without draining the heating circuit.
  17. M

    Danfoss hard wired thermostat problem x 2 in new build home with Ideal combi boiler

    You would have to modify the zone valve wiring as well or just disconnect the valve from the wiring centre completely so there is no call for heat.
  18. M

    Pump overrun while valves are shut

    The only way to do what the OP wants is to replace the CH motorised valve with a normally open valve to give a PDHW setup but without the ability to change flow temps in the boiler.
  19. M

    Boiler suggestion to replace potterton suprima 70

    Any quote needs to be based on the heat loss survey, I'm surprised BG can state the boiler size without having the heat loss figure.