  1. O

    Worcester Greenstar Heatslave 25/32 being weird.

    An engineer is required I'm afraid looks like could be a major bust can't say I've had one like that it looks like something major has happened.It would be interesting to find out what has actually gone wrong.Bob
  2. O

    Worcester Danesmoor 12/14 - Lockout

    Good luck hope it's fixed.Bob
  3. O

    Worcester Danesmoor 12/14 - Lockout

    I tHink the outlet pipe on the pump is leaking under pressure which is about 120 psi.Bob
  4. O

    Braided oil lines

    Ah boulter a boiler in it's own class I'm glad Andrew houndsfield has started up these boilers are miles ahead of the others he's a very nice chap to talk to by the way and their hoses are the dogs danglers.Bob
  5. O

    Grant Vortex Combi 26 random demand LED

    Nice one hairy my next port of call was the dhw or pcb I find the grants seem to go through pcbs quite often not cheap either.Bob
  6. O

    Grant Vortex Combi 26 random demand LED

    Check the flow switch and make sure there's no leak on the hot water
  7. O

    New oil boiler - condensate query

    The pipework outside should be 32 mm and why not put the condensate into a soak away just outside and cover it over to stop the frost I live on isle of Lewis and have no probs with it.Bob
  8. O

    How can i connect a pump to the incoming water mains?

    No you need a break tank to protect the water supply or else you'll be in deep do do.Bob
  9. O

    what is it?

    It's no wonder their always in danger of flooding in holland.Bob
  10. O

    Problems with Oil boiler / heat store set up.

    As usual an over complicated system it's all right for installers but they never tell the end user how it all works this thing outside which looks at what the temps going to be is a waste of fuel it's what's needed in the house what counts in my old fashioned head.Bob
  11. O

    Oil combi heatslave external service

    Nozzle every service hoses need checking replace every two years or five if using long life boiler needs cleaning if it got soot in it means baffles out and secondary heat ex looking at / cleaning plus general look over put back together then check fuel pressure analyser check on emissions check...
  12. O

    Changing taps on a y-plan system.

    Very good call T.Bob
  13. O

    Help with customers gurgling bath!!!

    Stick a hep2o trap on the bath.Bob
  14. O

    How to restart boiler - damsel in distress

    Another fault is the expansion hose gets blocked and you read the gauge and it shows pressure but the pressure isn't in the boiler as the hose is blocked.Bob
  15. O

    How to restart boiler - damsel in distress

    Hey ho pressure needs to be higher on a warmflow needs to be over 1.5bar and these switches jam for a hobby terrible things.Bob
  16. O

    How to restart boiler - damsel in distress

    A warmflow boiler check for a pressure switch.Bob
  17. O

    Replace Danfoss oilpump with Suntec

    What happens is a while ago to meet the emissions act oil firms took out some of the sulpher from the fuel oil as sulpher is a natural lubricant it played he'll with some pumps so you need to replace the oils lubricity,if you like you have to make the oil more slippery daft eh.Bob
  18. O

    Moving an oil boiler

    If I were you I'd not go under the house.I work for insurance companies and I deal with the clean up guys and wow do they go to town on a leak they dig down about 10 feet and sometimes take down Loads of the building,makes me feel sorry for the homeowners.Bob
  19. O

    Replace Danfoss oilpump with Suntec

    Danfoss are a supierior pump to suntec personally I wouldn't use a suntec danfoss are very good pumps it could be you need exocet in your oil.Bob